CONTROLS & CONNECTIONS

O

POW ER Switch

Q L/R INPUT Level Control

This dual concentric control permits independent adjustment of

left and right channel input levels. The irmer and outer controls

are friction-coupled so that once the left/right input level balance

has been set, the overall input level can be varied simply by

rotating the central control.

@

Level M eters & CLIP Indicators

Independent 8-segment LED level meters are provided for the

left and right channels. The meter display range is from -30 to 0

dB. The clip indicator lights at levels greater than +18 dBm

when the level control is set at “7” and the input level switch is

set to +4 dB.

O

LED M em ory Number D isplay

This 2-digit numeric display shows the number of the currently

selected memory location (1 — 90). When the LED display is

continuously lit, the effect corresponding to the number dis­

played is active. When the LED display is flashing, this indicates

that a new memory location has been selected but has not yet

been recalled, leaving the previously selected effect active.

©

LCD Panel

The LCD (Liquid Crystal Display) panel is the DEQ7’s main

parameter and data display. It displays 2 lines of 16 characters,

and is backlit for easy reading under any lighting conditions.

©

Parameter Editing Keys

The leftmost group of four keys on the DEQ7 front panel (PA­

RAMETER,

UP-ARROW,

DOWN-ARROW

and

DELAY/

LEVEL) are used to select and modify parameters within the

currently selected program. The PARAMETER and DELAY/

LEVEL keys are used to select the parameter to be edited, and

the arrow keys are used to change the value of the selected

parameter.

Pressing

the

PARAMETER

and

UP-ARROW

or

DOWN-ARROW

keys

together

causes

continuous

parameter

incrementing or decrementing.

©

Program Selection & Storage Keys

The central group of four keys (STORE, UP-ARROW, DOWN-

ARROW, RECALL) is used to select and recall any of the preset

ROM programs (numbers 1 through 30) or user-edited programs

in the RAM area (numbers 31 through 90). The STORE key

allows edited programs to be stored in any RAM memory loca­

tion (31 through 90).

O U TILITY Key

The UTILITY key accesses a number of utility functions includ­

ing program title editing, MIDI bank and channel control, MIDI

program change to memory number assignment, MIDI bulk

dump control and seconds or feet display selection.

©

PRO TECT O N ¡O FF Key

The PROTECT ON/OFF key is used to “lock” the DEQ7 set­

tings so that they can be inadvertently changed. To set the PRO­

TECT ON mode, hold down the PROTECT key and press the

parameter up-arrow key. To disengage the PROTECT mode hold

the PROTECT key and press the parameter down-arrow key.

PROTECT cannot be turned ON while the MEMORY display is

flashing.

® BYPASS Key

When the BYPASS key is pressed and its LED indicator lights,

the selected EQ program is completely bypassed and the direct,

unequalized signal is fed to the unit’s output connectors. Press

the BYPASS key a second time (the LED indicator will go out)

to restore normal EQ operation.

©

FO O T CO NTRO L Jack

An optional foot controller (Yamaha FC7) can be connected here

to allow foot control of the dynamic EQ program filter parame­

ters.

®

BYPASS Jack

An optional footswitch (Yamaha FC4 or FC5) connected here

performs the same function as the BYPASS key ® .