STIEBEL ELTRON SOL 25 PLUS User Manual

Page 10

Advertising
background image

10

| SOL 25 PLUS

WWW.STIEBEL-ELTRON-USA.COM

Figure 2: Collector Temperature Sensor Well

Storage Tank

In a standard residential solar heating system, one to three
collectors are connected in series to a solar storage tank of 80-
163 gallons capacity. Refer to the tank installation instructions for
details.

Storage Tank Temperature Sensor

The temperature sensor for the SBB tanks is inserted into the sensor
well of the lower internal smooth-tube heat exchanger (only the SBB
Plus tanks have an upper heat exchanger). Coat the collector sensor
with heat-conducting paste and insert it into the sensor well until it
bottoms out. It is very important that the sensor make full contact
(without gaps or voids) to the inside of the sensor well’s walls.
Secure the sensor and its lead (e.g. cable tie).

Installation Example

A general system schematic diagram of components and pipe
arrangements for a typical Stiebel Eltron SOLKIT domestic hot water
(DHW) heating system with both solar heating and alternative
afterheating (or reheating) with a boiler is shown in

Figure 3.

Temperature sensor

with heat conducting paste

Thermal insulation

Roof outlet/duct

(corrugated hose)

Heat transfer medium

(flow direction)

Collector sensor well

Fitting

2

Advertising