8.6 Checklist for Start-up Of Solar Installations

CAUTION: IT IS MANDATORY TO PERFORM THE WORk
IN COMPLIANCE WITH THE “SAFETY REGULATIONS FOR

WORk ON AND INVOLVING ROOFS“ AND THE INSTRUCTIONS
“SAFETY AND RESCUE HARNESSES“ PUBLISHED BY THE TRADE
ASSOCIATION. THESE ASSEMBLY AND OPERATING INSTRUCTIONS
AND THE ASSEMBLY AND OPERATING INSTRUCTIONS FOR THE SOM
CONTROLLER AND THE STORAGE SYSTEM ARE TO BE FOLLOWED
DILIGENTLY DURING THE ASSEMBLY WORk.

Upon the start-up of solar installations provided with Stiebel Eltron
Flat Plate Collectors, the following checklist should be reviewed to
help ensure successful completion of the installation.

Installation Operator:

Fitting Company:

Name:

Name:

Street:

Street:

City:

City:

Solar Circuit

Yes

No

Are the collectors installed in their mounting frames in the proper position and secured tightly (free of play) with the top and the bottom screws?

Has the installation of the pipework between the collectors and the pumping station been performed according to Stiebel Eltron installation
instructions?

Has all the pipework in the solar collector loop been hard-soldered?

Has all the pipework been insulated?

Is the pressure relief safety valve (87 psi) and the vent installed according to Stiebel Eltron installation instructions?

Was the pressure and leak test performed?

Is the solar loop filled using only the premixed 50% GRAS Propylene Glycol and deionized water heat-transfer medium?

Have labels been installed on all valves, tank and pipework?

Are the shut-off valves open, and is the check valve set (per pumping station assembly instructions)?

Is the collector temperature sensor mounted at the specified position at the outlet pipe of the collector(s) and electrically connected to the
controller?

Has the electrical wiring been performed in accordance with the Stiebel Eltron controller wiring diagram?

Is the solar controller set according to the assembly and operating instructions?

Has the test run of the circulation pump been performed? Checked for excessive/unusual noise? Checked for proper heat collection and storage
during insolation?

hot Water Circuit

Yes

No

Has the solar storage system (tank) been installed to the domestic water pipes according to Stiebel Eltron instructions and all local regulations?

Has the temperature sensor in the solar storage system (tank) been mounted and electrically connected to the controller according to Stiebel
Eltron instructions and all local regulations?

Has the backup water heater (afterheating or reheating) been tested and properly installed for re-heating?
If so, specify the equipment connected and its temperature settings:



Is the SOM controller properly grounded electrically?

Was the lightning protection equipment connected by authorized skilled personnel?

Is the solar controller set according to the assembly and operating instructions?

Has the test run of the circulation pump been performed? Checked for excessive/unusual noise? Checked for proper heat collection and storage
during insolation?