Assigning id numbers, Assigning id numbers -5 – KEYENCE DL-EP1 User Manual
Page 21

2-2 Installation and Connection to Sensor Amplifiers
2-5
2
Connec
tion and
Con
fig
ur
ati
on
- EtherNet/IP Compatible Network Unit DL-EP1 User’s Manual (SK-1000) -
3
Mount the supplied end units (OP-26751: a set of two pieces) on the outer
ends of the amplifier and the EtherNet/IP Compatible Network Unit DL-
EP1. Then, fix the end units with the screws on the top of each end unit (2
points x 2 units). (Tightening torque : 0.6 Nm or less)
Mount the end units in the same way as the EtherNet/IP Compatible Network
Unit DL-EP1.
Several sensor amplifiers can be connected to the DL-EP1. ID numbers for data
identification are assigned to each sensor amplifier.
The method for assigning ID numbers is as follows:
• ID numbers are assigned in order, starting from the sensor amplifier that is the
main unit. (Optional numbers cannot be assigned.)
• 0 is assigned as the ID number of the DL-EP1.
• You cannot change the ID numbers assigned to the sensor amplifiers.
• In this manual, ID number 00 to ID number 08 are denoted as ID00 to
ID08, respectively.
Also for cyclic communication, output, current value, and external input are assigned
one by one per ID number.
For DIN rail mount type
Press the EtherNet/IP Compatible Network Unit DL-EP1, into
full engagement with the sensor amplifier. Energizing the DL-
EP1 when not inserted fully may damage the DE-EP1.
End unit
End unit
NOTICE
Assigning ID Numbers
Point
ID number
01
Main
unit
Expansion
unit
Expansion
unit
Expansion
unit
02
07
08
00