4 message communication, Commu nic ati ng wi th t he sk-1000 s eries – KEYENCE DL-EP1 User Manual
Page 67

3-4 Message Communication
3-39
3
Commu
nic
ati
ng
wi
th t
he SK-1000
S
eries
- EtherNet/IP Compatible Network Unit DL-EP1 User’s Manual (SK-1000) -
Group1
0338H
(824)
Current system
parameters
*7
Indicates the current status of the system
parameters. Use this attribute to check the
system parameters with which the sensor
amplifier is actually operating.
The corresponding bit turns on according to
the current status.
bit 0:
0:NPN
1:PNP
bits 1, 2 and 3 (For main unit only. Fixed to 000
for expansion unit)
000: Analog output OFF
001: 0 to 5 V
010: -5 to +5 V
011: 1 to 5 V
100: 4 to 20 mA
R
DINT
0339H
(825) to
033FH
(831)
(Reserved for system)
Group2
0340H
(832)
Group2 Entry
count
Indicates the No. of Group 2 entries.
Parameter range: 17
R
DINT
0341H
(833)
HI setting value
(BANK 0)
Set up setting value of HI side (BANK 0).
Parameter range: -99.999 to +99.999
(initial value: +1.000)
R/W
DINT
0342H
(834)
LO setting value
(BANK 0)
Set up setting value of LO side (BANK 0).
Parameter range: -99.999 to +99.999
(initial value: -1.000)
R/W
DINT
0343H
(835) to
0345H
(837)
(Reserved for system)
0346H
(838)
HI setting value
(BANK 1)
Set up setting value of HI side (BANK 1).
Parameter range: -99.999 to +99.999
(initial value: +1.000)
R/W
DINT
0347H
(839)
LO setting value
(BANK 1)
Set up setting value of LO side (BANK 1).
Parameter range: -99.999 to +99.999
(initial value: -1.000)
R/W
DINT
0348H
(840) to
034AH
(842)
(Reserved for system)
034BH
(843)
HI setting value
(BANK 2)
Set up setting value of HI side (BANK 2).
Parameter range: -99.999 to +99.999
(initial value: +1.000)
R/W
DINT
034CH
(844)
LO setting value
(BANK 2)
Set up setting value of LO side (BANK 2).
Parameter range: -99.999 to +99.999
(initial value: -1.000)
R/W
DINT
034DH
(845) to
034FH
(847)
(Reserved for system)
0350H
(848)
HI setting value
(BANK 3)
Set up setting value of HI side (BANK 3).
Parameter range: -99.999 to +99.999
(initial value: +1.000)
R/W
DINT
0351H
(849)
LO setting value
(BANK 3)
Set up setting value of LO side (BANK 3).
Parameter range: -99.999 to +99.999
(initial value: -1.000)
R/W
DINT
Class
Attribute
ID
Name
Description
Attribute
Data