KEYENCE DL-EP1 User Manual
Page 68

- EtherNet/IP Compatible Network Unit DL-EP1 User’s Manual (SK-1000) -
3-4 Message Communication
3-40
3
Commu
nic
ati
ng
wi
th t
he SK-1000
S
eries
Group2
0352H
(850) to
035FH
(863)
(Reserved for system)
Group3
0360H
(864)
Group3 Entry
count
Indicates the No. of Group 3 entries.
Parameter range: 9
R
DINT
0361H
(865)
Key lock
function
Sets key lock.
Parameter range: 0 to 1 (initial value: 0)
0: Unlock
2: Key lock
R/W
DINT
0362H
(866)
Bank function
For read:
Reads the current attribute. Use "Bank status"
(032BH (811)) to check the bank No. for which
the sensor amplifier is operating.
Parameter range: 0 to 3 (initial value: 0)
For write:
To use this attribute to change the bank No.,
set "Bank switching method" (0396H (918)) to
"Button". The change is disabled when
"External input" is set.
Parameter range: 0 to 3
0: Switches to bank 0.
1: Switches to bank 1.
2: Switches to bank 2.
3: Switches to bank 3.
R/W
DINT
0363H
(867)
Timing input
*8
Set up status of timing input.
Use "Timing status" (032CH (812)) to check
the timing input status under which the sensor
amplifier is operating.
The sensor amplifier operates based on the
OR of the external input cable and cyclic
communication statuses.
Parameter range: 0 to 1 (initial value: 0)
0:Timing input OFF
1:Timing input ON
R/W
DINT
0364H
(868) to
0367H
(871)
(Reserved for system)
0368H
(872)
Sub display's
screen
Set up sub display's screen.
Parameter range: 0 to 5 (initial value: 0)
0: Temperature and humidity
1: Temperature
2: Humidity
3: HI setting value
4: LO setting value
5: RV
R/W
DINT
Class
Attribute
ID
Name
Description
Attribute
Data
Type