KEYENCE DL-RS1A/IB User Manual

Page 15

Advertising
background image

13

Parameters of Commands and Responses

z Read/write data

The following table lists the types of data that can be read from and written to IB Series sensor
amplifiers.

When data is written while the initial reset is being performed, the parameter error will occur
(Error number: 22). When writing data after the initial reset is performed, confirm that the
EEPROM writing result (Data number: 053) shows "1: Normal termination" and then write
data.

Data

No.

Data name

Data

format

*1

No. of

bytes

Attribute

*2

Data range

Default value

001

Zero shift request

*

1

R

0 - 1: Last written value

1

W

0

o 1: Perform zero shift*

3

002

Zero shift reset request

*

1

R

0 - 1: Last written value

1

W

0

o 1: Perform zero shift reset*

3

003

Reset request

*

1

R

0 - 1: Last written value

1

W

0

o 1: Perform reset*

3

004

Error clear request

*

1

R

0 - 1: Last written value

1

W

0

o 1: Perform error clear *

3

*

4

005

Initial reset request

*

1

R

0 - 1: Last written value

1

W

0

o 1: Perform initial reset*

3

006

System parameter set request*

5

*

1

R

0 - 1: Last written value

1

W

0

o 1: Perform system parameter set*

3

010

Reference light registration

request

*

1

R

0 - 1: Last written value

1

W

0

o 1: Perform reference light amount

registration

011

Adjust request

*

1

R

0 - 1: Last written value

1

W

0

o 1: Perform adjust*

3

012

Adjust reset request

*

1

R

0 - 1: Last written value

1

W

0

o 1: Perform adjust reset*

3

014

Tolerance tuning request

*

1

R

0 - 1: Last written value

1

W

0

o 1: Perform tolerance tuning*

3

015

2-point tuning HIGH side 1st

request

*

1

R

0 - 1: Last written value

1

W

0

o 1: Perform 2-point tuning HIGH side 1st

point*

3

016

2-point tuning HIGH side 2nd

request

*

1

R

0 - 1: Last written value

1

W

0

o 1: Perform 2-point tuning HIGH side

2nd point*

3

017

2-point tuning LOW side 1st

request

*

1

R

0 - 1: Last written value

1

W

0

o 1: Perform 2-point tuning LOW side 1st

point*

3

018

2-point tuning LOW side 2nd

request

*

1

R

0 - 1: Last written value

1

W

0

o 1: Perform 2-point tuning LOW side 2nd

point*

3

019

Measured correction 1st

request*

6

*

7

*

1

R

0 - 1: Last written value

1

W

0

o 1: Perform measured correction 1st

point*

3

020

Measured correction 2nd

request*

6

*

7

*

1

R

0 - 1: Last written value

1

W

0

o 1: Perform measured correction 2nd

point*

3

026

Logical correction 1st request*

6

*

7

*

1

R

0 - 1: Last written value

1

W

0

o 1: Perform logical correction 1st point*

3

027

Logical correction 2nd request*

6

*

7

*

1

R

0 - 1: Last written value

1

W

0

o 1: Perform logical correction 2nd point*

3

Point

Parameters of Commands and Responses

065

HIGH setting value (BANK 0)

±***.** *

8

7

R/W

-999.99 to +999.99

20.00

066

LOW setting value (BANK 0)

±***.** *

8

7

R/W

-999.99 to +999.99

10.00

067

Shift target value (BANK 0)

±***.** *

8

7

R/W

-999.99 to +999.99

0.00

068

HIGH setting value (BANK 1)

±***.** *

8

7

R/W

-999.99 to +999.99

20.00

069

LOW setting value (BANK 1)

±***.** *

8

7

R/W

-999.99 to +999.99

10.00

070

Shift target value (BANK 1)

±***.** *

8

7

R/W

-999.99 to +999.99

0.00

071

HIGH setting value (BANK 2)

±***.** *

8

7

R/W

-999.99 to +999.99

20.00

072

LOW setting value (BANK 2)

±***.** *

8

7

R/W

-999.99 to +999.99

10.00

073

Shift target value (BANK 2)

±***.** *

8

7

R/W

-999.99 to +999.99

0.00

074

HIGH setting value (BANK 3)

±***.** *

8

7

R/W

-999.99 to +999.99

20.00

075

LOW setting value (BANK 3)

±***.** *

8

7

R/W

-999.99 to +999.99

10.00

076

Shift target value (BANK 3)

±***.** *

8

7

R/W

-999.99 to +999.99

0.00

097

Key lock setting

*

1

R/W

0: Disabled

1: Key lock

0

098

Bank setting*

9

*

1

R/W

0: Switch to bank 0

1: Switch to bank 1

2: Switch to bank 2

3: Switch to bank 3

0

099

Timing input*

10

*

1

R/W

0: Timing input OFF

1: Timing input ON

0

100

Laser emission stop input*

10

*

1

R/W

0: Laser emission stop input OFF

1: Laser emission stop input ON

0

104

Sub display's screen

*

1

R/W

0: R.V. value screen

1: Analog output screen

2: HIGH setting value screen

3: LOW setting value screen

4: Shift target value setting screen

0

105

System parameter*

11

**

2

R/W

Main unit: 0 to 9

Expansion unit: 0 to 1

0

106

Tolerance tuning setting width

***.** *

12

6

R/W

0.00 to 999.99

10.00

107

Calibration function

*

1

R/W

0: Do not correct (Initial state)

1: Measured correction

2: Logical correction

0

108

Measured/Logical correction

target 1*

6

*

7

±***.** *

8

7

R/W

-999.99 to +999.99

0.00

109

Measured/Logical correction

target 2*

6

*

7

±***.** *

8

7

R/W

-999.99 to +999.99

100.00

115

Logical correction measured 1*

6

*

7

±***.** *

8

7

R/W

-999.99 to +999.99

0.00

116

Logical correction measured 2*

6

*

7

±***.** *

8

7

R/W

-999.99 to +999.99

100.00

130

Measurement mode*

13

*

1

R/W

0: % mode

1: Dimension mode

0

131

Received/Blocked light mode

*

1

R/W

0: Received light mode

1: Blocked light mode

0

Data

No.

Data name

Data

format

*1

No. of

bytes

Attribute

*2

Data range

Default value

Advertising