Parameters of Commands and Responses

133

Averaging/High-pass filter

**

2

R/W

Averaging

0: 1

1: 2

2: 4

3: 8

4: 16

5: 64

6: 256

7: 1024

8: 4096

9: 16384

High-pass filter

10: 0.1Hz

11: 0.2Hz

12: 0.5Hz

13: 1Hz

14: 2Hz

15: 5Hz

16: 10Hz

17: 20Hz

18: 50Hz

19: 100Hz

5

134

Output mode

*

1

R/W

0: NO (Normally Open)

1: NC (Normally Close)

0

136

Hold function setting

*

1

R/W

0: Sample hold

1: Peak hold

2: Bottom hold

3: Peak-to-peak hold

4: Auto peak hold

5: Auto bottom hold

0

137

Auto hold trigger level

±***.** *

8

7

R/W

-999.99 to +999.99

90.00

138

Timing input

*

1

R/W

0: Level

1: Edge

0

139

Delay Timer

*

1

R/W

0: Delay timer off

1: On delay timer

2: Off delay timer

3: One shot timer

0

140

Timer duration

****

4

R/W

1 to 9999

60

141

Hysteresis

***.** *

12

6

R/W

0.00 to 999.99

0.00

142

Analog output scaling*

14

*

1

R/W

0: Do not scale (Initial state)

1: Free range

0

143

Analog output upper limit*

14

±***.** *

8

7

R/W

-999.99 to +999.99

100.00

144

Analog output lower limit*

14

±***.** *

8

7

R/W

-999.99 to +999.99

0.00

145

External input setting*

15

*

1

R/W

0: Initial state

1: User setting

0

146

External input 1 function

selection*

15

*

1

R/W

0: Zero shift input

1: Bank A input

2: Bank B input

3: Laser emission stop input

4: Not use

0

147

External input 2 function

selection*

15

*

1

R/W

0: Reset input

1: Bank A input

2: Bank B input

3: Laser emission stop input

4: Not use

0

148

External input 3 function

selection*

15

*

1

R/W

0: Timing input

1: Bank A input

2: Bank B input

3: Laser emission stop input

4: Not use

0

Data

No.

Data name

Data

format

*1

No. of

bytes

Attribute

*2

Data range

Default value

Parameters of Commands and Responses

*1

In the Data format column, "±" indicates that the value can be either "+" or "-" and "*" signifies a
number from "0 to 9".

*2

Indicates that the data can only be read from (R), can only be written to (W), or can be both read
from and written to (R/W) the sensor amplifiers.

*3

The command is executed only when the data is changed from 0 to 1. Unless the setting is
changed to 1 after the setting is changed to 0, the command is not executed.
If the sensor amplifier is turned OFF after the zero shift is performed, the previous state before
the zero shift function is used is restored. If you wish to keep the zero shift state even after the
power is turned OFF, set the Save zero-shift state function to ON.
If the sensor amplifier is turned OFF after the adjust function is performed, the previous state
before the adjust function is performed is restored. If you wish to keep the light amount
correction value even after the power is turned OFF, set the Save adjust state function to ON.

*4

Reference light amount registration error [ErG] and Adjust error [ErAdJ] are cleared.

*5

The system parameter means the polarity of judgment output and check output, and the setting
for analog output.
The execution result can be confirmed by the data number 056 (System parameter current state).

*6

When requesting execution of the Measured correction (Logical correction), the data No. "107"
must be set to Measured correction (Logical correction) before setting.

149

External input 4 function

selection*

15

*

1

R/W

0: Adjust input

1: Bank A input

2: Bank B input

3: Laser emission stop input

4: Not use

4

150

Bank switching method

*

1

R/W

0: Button

1: External input

0

152

Save zero-shift state function

*

1

R/W

0: OFF

1: ON

0

154

Display digit

*

1

R/W

0: Initial state

1: 0.0001

2: 0.001

3: 0.01

4: 0.1

5: 1

0

155

Power save function

*

1

R/W

0: OFF

1: Half

2: All

0

157

Judgment indicator color

*

1

R/W

0: GO only Green (Initial state)

1: GO only Red

2: All Green

3: All Red

0

158

P.V. value display color

*

1

R/W

0: GO Green (Initial state)

1: GO Red

2: All Green

3: All Red

0

161

Save adjust state function

*

1

R/W

0: OFF

1: ON

0

162

Adjust level

**

2

R/W

1 to 30

20

163

Auto adjust function

*

1

R/W

0: Disabled

1: Enabled

0

164

Auto adjust level

**.**

5

R/W

0.50 to 20.00

3.00

165

Check output function

*

1

R/W

0: Disabled

1: Enabled

0

166

Check output light level

**

2

R/W

1 to 30

10

167

Error output mode

*

1

R/W

0: Normal mode (Initial state)

1: LX2 compatible mode

0

168

Hysteresis for trigger level

*

1

R/W

0: Initial state

1: User setting

0

169

Hysteresis set value for trigger

level

***.** *

12

6

R/W

0.00 to 999.99

1.00

Data

No.

Data name

Data

format

*1

No. of

bytes

Attribute

*2

Data range

Default value

Advertising