7

Communication Specifications

This section provides the communication specifications of DL-RS1A and describes how to configure the unit.

Communication Specifications

The following table lists the communication specifications for DL-RS1A.

For communication settings, refer to page 2.

Sensor Amplifier ID Number Assignments

When the main sensor amplifier that is connected to DL-RS1A supports expansion units, the main
sensor amplifier ID number "00" is automatically assigned to the main unit and ID numbers "01 to 14"
to the expansion units.

You cannot change the assignment of sensor amplifier ID numbers.

„ DIN rail mount sensor amplifiers

„ Panel mount sensor amplifiers

Item

Specifications

Communication method Full duplex

Synchronization method Asynchronous

Transmission code

ASCII

Communication speed

2400, 4800, 9600, 19200, 38400 bit/s (Factory default: 9600 bit/s)

Data bit length

7 or 8 bits (Factory default: 8 bits)

Parity check

None, even, odd (Factory default: none)

Stop bit length

1 bit

Data delimiter

Receive: automatically detect CR or CR + LF

Send: fixed to CR + LF

Point

ID No. 00

Main

Exp.

Exp.

Exp.

Exp.

01

02

04

05

Sensor amplifier

DL-RS1A

ID No.

Sensor amplifier

00

01

02

04

05

Main

Exp.

Exp.

Sensor amplifier

Exp.

Exp.

DL-RS1A

Commands and Responses

Overview of Commands and Responses

„ Command format

You can send specific commands based on ASCII codes from an external device to DL-RS1A.
For information on the parameters used in the command, refer to "Parameters of Commands and
Responses" (page 10).

Sample command format structure

(1) With the first two bytes, specify the communication command.
(2) Specify the ID number assigned to the target sensor amplifier using two digits (ASCII characters).
(3) Specify the data number for the data you want to read from or write to the sensor amplifier using

three digits (ASCII characters).

(4) Insert CR or CR + LF as the command delimiter.

You must use commas (,) to separate (1), (2), and (3).

To read the "Hold function setting (data number: 136)" from an expansion unit of an active
IB Series (ID number: 01):

From an external device, 11-byte data will be sent to the DL-RS1A.

The last byte of the command you send must be CR (0DH) or LF (0AH). Specifying a value
other than CR or LF results in an error response (error number: 00). For information on the
error responses, refer to "Error numbers" (page 16).

ID No. 00

Main

Exp.

Exp.

Exp.

Exp.

01

02

04

05

Sensor amplifier

DL-RS1A

External device like PLC or PC

Response

or

error response

Command or DRQ input

S

(1)

(2)

(3)

(4)

R

CR LF

ID No.

Data No.

,

,

Important

Example

S

(53H) (52H)

(2CH)(31H) (33H) (36H)(0DH)(0AH)

(2CH)(30H) (31H)

R

CR LF

0 1

1 3 6

,

,

Command :

S

(53H)

,

(2CH)

R

(52H)

0

(30H)

1

(31H)

1

(31H)

,

(2CH)

3

(33H)

6

(36H)

LF

(0AH)

CR

(0DH)

ASCII character conversion :

Data memory 0

Data memory 1

Data memory 2

Data memory 3

Data memory 4

Data memory 5

→ 5352

H

Value to store in
data memory (hexadecimal)

→ 2C30

H

→ 312C

H

→ 3133

H

→ 360D

H

→ 0A00

H

bit
15

bit

0

Important