10

GT2-500-M-E

● Air cylinder type

*1

When the surrounding temperature is 20°C.

*2

This is a typical value at the center of the measuring range. The measuring force varies depending on the mounted condition of the dust boot.

*3

Connect an air tube to the exhaust valve so that no foreign materials enter from the valve.

*4

When using mounting bracket D (OP-84327) with GT2-A32/A50, vibration is 0.75 mm.

*5

The contact is a separately sold option.

Amplifier

*

Precautions on use when units are added
3 units in total (15 sensor heads in total) – 1 main unit and 2 expansion units – can be added to the amplifier.
Be sure to mount the units (pre-mounted on metal plating) onto a DIN rail, and use an end unit (OP-26751) when expanding.
Furthermore, check the specification limits below for the number of expansion units.

Up to 3 units, including a main unit

Make sure that the Communication Unit output current is 10 mA or below.

Model

GT2-A12K

GT2-A12KL

GT2-A12

GT2-A12L

GT2-A32

GT2-A50

Detection system

Scale shot system II Absolute type (without tracking error)

Measuring range

12 mm

32 mm

50 mm

Resolution

0.1 µm

0.5 µm

Indication accuracy

*1

1 µm (P-P)

2 µm (P-P)

3 µm (P-P)

3.5 µm (P-P)

Measuring

force

*2

When installed
facing down

1.2 N

0.4 N

1.2 N

0.4 N

2.1 N

3.2 N

When installed
sideways

1.1 N

0.3 N

1.1 N

0.3 N

1.8 N

2.8 N

When installed
facing up

1.0 N

0.2 N

1.0 N

0.2 N

1.5 N

2.4 N

Sampling interval

1 ms

Operation indicator

2-color LED (red, green)

Pressure range

0.25 to 0.5 MPa

Max. pressure

1.0 MPa

Fluid to use

Dry air

Environmental
resistance

Enclosure rating

IP67

*3

-

IP67

*3

-

IP67

*3

Surrounding
air temperature

0 to +55°C (No freezing)

Relative humidity

35 to 85% RH (No condensation)

Vibration

*4

10 to 55 Hz, Compound amplitude 1.5 mm, 2 hours each in X, Y, and Z axis

Shock resistance

1000 m/s

2

(IEC60068-2-27)

-

Material

Main unit

Main unit cover: zinc die-cast, Cylinder: aluminum alloy, Air coupling socket (resin part): polyacetal, Air coupling socket (metal part): nickel plated brass, Indicator: polyarylate (PAR)

Dust boot

FKM

-

NBR

-

NBR

Contact point

*5

SUS304, tungsten

carbide

SUS304, SUS440C

SUS304, SUS440C

Sensor head cable

Sold separately (connected to M8 connector)

Weight (excluding sensor
head cable)

Approx. 145 g

Approx. 340 g

Approx. 405 g

Model

GT2-500

GT2-550

Main unit/Expansion unit

Main unit

Expansion unit

Type

Mount type

DIN rail mount

Number of units that can be added

*

2 units (up to 15 sensor heads)

Supply voltage

20 to 30 V DC, including 10% ripple (P-P) (power is supplied to GT2-550 from the main unit)

Current consumption

4500 mW max. (150 mA max. at 30 V)

Response time

hsp (3 ms), 5 ms, 10 ms, 100 ms, 500 ms, 1000 ms

(hsp (12 ms), 20 ms, 40 ms, 400 ms, 2000 ms, 4000 ms when using GT2-P***/PA*** with a sensor head)

Environmental
resistance

Surrounding air
temperature

-10 to +50

Relative humidity

35 to 85% RH (No condensation)

Vibration resistance

10 to 55 Hz, Compound amplitude 1.5 mm, 2 hours each in X, Y, and Z axis

Material

Main unit cover: Polycarbonate, Cable: PVC

Weight

Approx. 140 g

Approx. 95 g

0

1

2

3

4

5

6

7

8

9

10 11 12

Measuring force (N)

Spindle retracted

Spindle extended

Table 1. Relationship between spindle position and measuring force grouped according to used air pressure.

(When installing side mounting, the measuring force is -0.05 N. When installing upward mounting, the measuring force is -0.1 N.)