Troubleshooting

When there is a malfunction, the status light on the sensor amplifier
lights in red.
If you are using a DL Series Communication Unit (excluding DL-RB1A),
details of the error can be checked via the Communication Unit. See
the DL Series manuals for information on using the Communication
Units.

Item

Reference

chapter

Origin Alignment

Chapter 3

Setting the Tolerances

Chapter 3

HH/Setting the HH/LL Criterion Value

Chapter 3

Preset Function (Adding or Subtracting a Desired Value)

Chapter 3

Bank Function (Registering Multiple Criterion Values and
Preset Values)

Chapter 3

Reset Input (Resetting Internal Values)

Chapter 3

Hysteresis

Chapter 3

Initialization (Initial Reset)

Chapter 3

Judging with the Current Value

Chapter 4

Judging after the Detection Value is Stabilized

Chapter 4

Judging by the Maximum Value (Peak Hold)

Chapter 4

Judging by the Minimum Value (Bottom Hold)

Chapter 4

Judging with the Difference between Maximum and
Minimum Values (Peak to Peak Hold Detection Mode)

Chapter 4

Holding HIGH/LOW Output (NG Hold)

Chapter 4

Detection Mode

Chapter 5

Hold Update Method

Chapter 5

Response time

Chapter 5

Timing Type

Chapter 5

Self-timing Level

Chapter 5

Self Timing Delay Types

Chapter 5

User-specified Delay Time

Chapter 5

Static Hold Delay Stability

Chapter 5

Static Hold Delay Stability Width

Chapter 5

Measurement Direction

Chapter 5

Multiplier

Chapter 5

Batch Input Settings

Chapter 5

Special Output Setting

Chapter 5

Limit Output HH Side Teaching

Chapter 5

Limit Output HH Side Criterion Position Setting

Chapter 5

Limit Output LL Side Teaching

Chapter 5

Limit Output LL Side Teaching Criterion Position Setting

Chapter 5

Select Preset Data

Chapter 5

Store Preset Value

Chapter 5

Preset Point

Chapter 5

Power Save Function

Chapter 5

Jam Detection Function

Chapter 5

Jam Detection Teaching

Chapter 5

Jam Detection Checkpoint Setting

Chapter 5

Calculation Setting Mode

Chapter 5

Timing Chart

Chapter 5

Item

Reference

chapter

List of Optional Parts

Chapter 1

Replacing the Contact

Appendix

Replacing the Dust Boot

Appendix

How to Mount the Lift Lever

Appendix

Problem

Cause

Corrective action

Sensor head
error

• The sensor head is

disconnected.

• The sensor head cable is

broken.

• The sensor head is

damaged.

• Connect the sensor

head.

• Replace the sensor

head cable.

• Replace the sensor

head.

EEPROM
error

• Failed to write data.

• Turn the equipment off

and on, and perform
initial reset. (If this
does not solve the
problem, the
equipment may be
damaged, or may have
reached the end of its
service life. Replace
the amplifier unit.)

Jam
detection
error

• The spindle is jammed.

(When using the jam
detection function)

• If the spindle is

jammed and does not
move, replace the
sensor head.
Use a Communication
Unit to check that the
timing input is
appropriate.

Self timing
delay error

• The value fell below (rose

above) the timing level
during the set delay time.

• The value fell below (rose

above) the timing level
before the detection status
was stable and the
criterion level (P.V. value)
was fixed when using
static hold internal timing.

• The value rose above (fell

below) the timing level,
then fell below (rose
above) the timing level
before the criterion level
(P.V. value) was fixed when
using delay timer internal
timing.

• Make sure that the

value does not fall
below (rise above) the
timing level before the
criterion value is fixed.
Alternatively, lengthen
the static hold delay
stabilizing amplitude
so that the criterion
value can be easily
fixed.

Unit number
error

• When using the calculation

function, the number of the
expansion unit when the
power is turned ON differs
from the number of the
expansion unit in the
memory of the main unit
when the calculation is set.

• When using the calculation

function, a model other
than the GT2-500/70
Series is added.

• Reset the calculation

mode or perform initial
reset of the main unit.
Perform initial reset via
the Communication
Unit. See the DL
Series manuals for the
method.

Calculation
error

• When using the reference

difference calculation
function, an error occurred
in the main unit.
When using other than the
reference difference
calculation function, an
error occurred in an
expansion unit.

• Check each main/

expansion unit for the
cause of the error.

Calculation
only mode
error

• The sensor head is

connected to the main unit
in which the calculation
only mode is set.

• Remove the sensor

head from the main
unit or set a mode
other than the
calculation only mode.