Kistler-Morse KM ultrawave User Manual

Page 38

Advertising
background image

time. To scroll through the menus, use the Up and Down Arrow Keys.

Note: The controller must be in the Manual Mode (Auto LED off) to access the menus.

For example, the fi rst screen shows:

Press the Up Arrow Key for further options, e.g.:

UltraWave Series

10 Display

UltraWave Series

20 Calibration

f1, f2, And f3 Keys

The Function Keys — F1, F2, and F3 — are used for lower case characters

NAME

RAW

TEXT

%

QUICK

CONFIG

and special symbols when editing the display. From Scan mode, press
HOLD then F1 to display the raw target (in inches or centimeters) from
transducer face to processed echo. In fl ow mode, the backspace key
displays the raw target. Pressing F2 changes to bar graph mode. Pressing
F3 will initiate a quick confi guration or re-calibration of a channel (level
only). See

Appendix G

.

esc Key

The Esc Key has several functions:

• The Esc Key is used to back through the submenus one

menu level at a time. Pressing this key while in the Main Menu

returns the display to the RUN Mode.

• The Esc Key also has another function. The UltraWave Series

controller arrives from Kistler-Morse with a factory-set ID number

assigned to each channel. If you replaced the number with a

customer-defi ned ID during the Startup Procedure or in the

Display Menu, pressing the Esc Key while the display is in the

Manual Mode (Auto LED off) briefl y displays the factory-set ID.

(bAcKsPAce ArroW) Key

The Backspace key is used to back up the cursor on the LCD display when using the alphanumeric keypad.

“.” (Period) Key

When the controller is in the Manual Mode, pressing the “.” key briefl y displays the current controller software
revision letter and the date of the release.

The “.” key also functions as a decimal point when entering numbers in the math channel.

AlPhAnuMeric Keys And shift Key

The Alphanumeric Keys (also referred to as the keypad) are used to input numeric parameters during setup and
calibration and customer-defi ned IDs.

The Shift LED is located below the Auto LED on the faceplate. Pressing the Shift Key toggles the Shift LED on
and off. The effect is described below:

• Shift LED not illuminated — pressing an Alphanumeric Key types the number shown on the key.

• Shift LED illuminated — pressing an Alphanumeric Key types a letter labeled above the key. Pressing the

key repeatedly toggles the display through the three letters labeled above the key. When the desired letter
is displayed, pressing the Enter Key or a different Alphanumeric Key advances the cursor one space to
the right. See

Figure 8: Characters Available for Customer-Defi ned ID

.Enter Key

The Enter Key has several functions:

• The Enter Key is used to save in memory any parameter set up in the menus. For example, if you enter

an operating span value in the Main/Calibration/Span Menu, pressing the Enter Key saves it to memory.
The value remains in memory until a new value is entered.

• When entering a vessel ID, the Enter Key advances the cursor one space to the right.

• When the UltraWave Series controller is vessel monitoring in Manual Mode, pressing the Enter Key

toggles the display from numerical format to bar graph format. The display remains in the bar graph
format (even when the controller is turned off and back on again) until the Enter Key is pressed to toggle
back to the numerical format.

sensor Key

The Sensor Key allows you to copy parameters to a different channel while remaining in a particular menu function.
For example, assume the display is showing this screen for channel 2 under the Main/Calibration/Span Menu:

Note: The Sensor Key only works if you are at the “end” of a menu; i.e., where the screen allows you to enter a
value or select from a list of choices on the display. If you press the Sensor Key, the display changes to:

Figure 8: Characters Available for
Customer-Defi ned ID

34

97-1163-01 Rev. D

www.kistlermorse.com

Advertising