Kistler-Morse KM ultrawave User Manual

Page 91

Advertising
background image

2. Equation tries to take a square root of a negative number that is calculated as part of the equation (i.e.,

square root of (8-12).

3. Equation tries to take a natural log (ln) of a negative number or of 0.

4. Result from intermediate channel being input into this channel is too large. Solution: Correct and/or scale

the equation for the intermediate channel.

5. Result is too large to display. Solution: Scale down the result by using the divide function.

Menu tree & hot Keys

Following is a summary of the keyboard functions (hot keys) you can use when vessel monitoring.

• Switch from Auto Mode to Manual Mode or vice versa.

Press the Scan/Hold Key (Auto LED illuminates when the UltraWave Series is in Auto Mode).

• Scroll through the Channels when in Manual Mode (Auto LED off)

Press the Up Arrow or Down Arrow Key.

• Switch from Channel Monitoring to Menu Tree

Press the Menu Key while in the Manual Mode.

• Switch from Numerical display to Bar Graph display or vice versa for a particular channel

If you set up the bar graph (see Chapter 6, Display Menu), press the Enter Key while in the Manual Mode to
toggle between numerical display and bar graph display.

• View Raw Target (level applications only)

Press the F1 Key while in the Manual Mode to change the top line of the display to show the raw target. The raw
target is the ‘raw’ distance from the face of the transducer to the target, before averaging, tracking, filtering, etc.
are applied.

• View Temperature of

current Level
channel (level
applications only)

Press the F2 key
while in manual
mode to change the
top line of the
display, showing the
airspace
temperature.

• View other Flow

Parameters (flow
applications only)

While in the Manual

87

97-1163-01 Rev. D

www.kistlermorse.com

Advertising