Mode you can change the display to show any of the following parameters: Head (current head), Temperature
(current temperature), Total (total flow since the last time you reset the total flow to 0), MaxF (maximum flow
since the last time you reset), MinF (minimum flow since the last time you reset), AvgF (average flow since the
last time you reset), and RLY (number of setpoint relays for the channel). Press the F1 Key to cycle the top line
of the display, the F2 Key to cycle the bottom line of the display and the F3 key to cycle both at once.

• View Factory-Set ID

If you input a customer-defined ID, but want to see the factory-set ID for a channel, press the Esc Key while
in the Manual Mode.

• View Serial Address for a channel

Press the Esc Key while in the Manual Mode.

• Display Current UltraWave Series Software Revision letter and Date of Release

Press the “.” Key briefly while in the Manual Mode.

• Enter 6600 to Default

Defaults the system; as well as Pressing ENTER at power up.