CHAPTER 7 – MAINTENANCE

Page 94 of 210

AERCO International, Inc. • 100 Oritani Dr. • Blauvelt, NY 10913

OMM-0086_0D

03/20/14

Ph.: 800-526-0288

GF-133

7.4 O

2

SENSOR

The O

2

sensor (part no. 61026) is located on the back plate at the right side of the unit as shown

in Figure 7-2. As this Figure shows, there is also a gas suction line that supplies a sampling of
the exhaust gases from the exhaust manifold to ensure accurate sampling of the O

2

levels. The

sensor and the suction line may be hot, therefore allow the unit to cool sufficiently before
removing or replacing the O

2

sensor.

NOTE

The O

2

Sensor needs to be replaced only once every 5 years.

The O

2

Sensor is removed and inspected by performing the following procedural steps:

O

2

Sensor Maintenance Procedures

1. Set the ON/OFF switch on the control panel, to the OFF position. Disconnect AC power

from the unit.

2. Remove the rear right-side panel from the unit by removing the screws at the top and rear

(Figure 7-2).

3. Disconnect the O

2

sensor lead wire by pushing in on the release tab and pulling apart the

connector.

4. Next, loosen and remove the O

2

sensor and crush washer from the back plate using a

15/16" open-end wrench.

5. Thoroughly inspect the O

2

sensor. If corroded, the sensor should be replaced. Ensure that

the hole in the refractory is clean and that the gas sample suction tube is not clogged.

6. Reinstall the O

2

sensor and crush washer on the back plate.

7. Reconnect the sensor lead wire.

8. Reinstall the rear right side panel on the unit.