Appendix C Troubleshooting

Troubleshooting the Boot Process

C-6

Cisco 11500 Series Content Services Switch Hardware Installation Guide

78-13884-03

After the CSS performs the diagnostics, it boots the Offline Diagnostic Monitor
(OffDM) as indicated by the following message:

Booting OffDm @ 0xbfd70000

See the following section for the OffDM verification of the boot configuration
record and disk drive.

If the Booting OffDm message does not appear, a CSS 11501 component failure
or an SCM failure may have occurred; such a failure would not allow a software
download to start.

If this problem occurs for a CSS 11501, obtain technical assistance.

If this problem occurs for a CSS 11503 or CSS 11506:

1.

Power down the CSS.

2.

Reseat the SCM.

3.

Power up the CSS.

If reseating the module does not correct its failure, obtain technical
assistance.

Test_name

Provides the name of the test reporting the error; for example:

Uart Interrupt Test

PHY Reset Test

Failure_details

Provides information about the error; for example:

PHY Reset Register failed to clear. Addr: 0x12345678

Expected: 0x0 Actual:0xf

Table C-1

Fields in the Diagnostic Monitor Error Message (continued)

Field

Description