Table c-3 – Cisco 11500 Series User Manual

Page 145

Advertising
background image

C-15

Cisco 11500 Series Content Services Switch Hardware Installation Guide

78-13884-03

Appendix C Troubleshooting

Troubleshooting the CSS Power Supply

Table C-3

describes these LEDs and provide suggestions for correcting problems.

Table C-3

LEDs of the CSS 11506 Power Supply

LED State

Possible Problem

Recommended Action

AC OK or
I/P OK (DC power supply)

DC OK

On

On

There is no problem
with the power source
and the power supply.

Not applicable.

Off

Off

There is no power to the
power supply.

Ensure the supply has power.
Check the power switch, power
cord, and power source.

On

Off

The power supply failed. Remove and replace the power

supply. Refer to the reference
sheet that comes with the
replacement supply.

After you install the power supply,
the CSS automatically brings the
power supply into service.

Advertising