Troubleshooting the css 11506 fan module – Cisco 11500 Series User Manual

Page 148

Advertising
background image

Appendix C Troubleshooting

Troubleshooting the CSS Fans

C-18

Cisco 11500 Series Content Services Switch Hardware Installation Guide

78-13884-03

Troubleshooting the CSS 11506 Fan Module

The CSS 11506 has three fans in a single fan module. When the CSS starts up and
fans are operational, the following message appears:

CHMGR: All fans are present (3).

Note

This message is displayed only if the logging level is set to the Info-6 or Debug-7
level.

If a fan fails when the CSS starts up, or fails during its normal operation, the
following message appears:

CHMGR: Missing fans. Expected 3. Found number.

The number variable indicates the total number of functioning fans.

If the modules start to overheat in the chassis, the following message appears:

Temperature has reached x celsius for slot number

The x variable indicates the temperature of the module. The module in the
designated slot number is running a temperature that is too high.

When a fan failure occurs, you must replace the fan module to prevent the CSS
modules from overheating.