Door lock connectors, Front view of ac900 – FingerTec AC900 Installation Guide User Manual

Page 3

Advertising
background image

Door Lock Connectors

The terminal will trigger the alarm output (NO or NC) for the
following situations:
• Door forced open (A door sensor must first be installed)
• Door open time out (A door sensor must first be installed)
• Terminal has been illegally dismantled

Dry Contact

(Independent power supply for door lock)

• NO type door lock (NO-COM)

• NC type door lock (NC-COM)

Power Contact

(Using power from terminal to power on door lock)

• COM1 - +12V

Dry Contact

(Independent power supply for door lock)

• NO type door lock (NO-COM)

• NC type door lock (NC-COM)

Power Contact

(Using power from terminal to power on door lock)

• NO type door lock (NO-GND)

• NC type door lock (NC-GND)

Alarm System

(NO or NC Type – Check in Advance Options)

Door Bell

Door Sensor (SEN-GND)

Release Button(BUT-GND)

WIRING PORT USAGE

COM

NO

NC

AL+

AL-

BEL+

BEL-

SEN

GND

BUT

Diagram1 • Normally Close (NC)

Diagram 2 • Normally Open (NO)

Diagram 3 • Other Accessories

GND
PWR
COM

NO
NC

GND

AL+

AL-

BUT

GND

B+

B-

DC12V 3A

Power Supply

DC12V Electronic

+

Door Lock (Type NC) ---

Emergency Break

2

Glass (Type NC)

3

Overwrite Keyswitch A

(Type NC)

C

Push Release Button

GND
PWR
COM

NO
NC

GND

AL+

AL-

BUT

GND

B+

B-

DC12V 3A

Power Supply

DC12V Electronic

+

Door Lock (Type NO) ---

Emergency Break

1

Glass (Type NO)

3

Overwrite Keyswitch B

(Type NO)

D

Push Release Button

GND
PWR
COM

NO
NC

GND

AL+

AL-

BUT

GND

B+

B-

*Door Sensor, Alarm, Doorbell.

DC12V 3A

Power Supply

Alam Device

Doorbell

Appendix II

Terminal Dimensions and Measurements

Appendix I

Power Supply & Door Lock System Wiring Diagrams

Front View of AC900

Advertising