Diagram1 • Normally Close (NC)

Diagram 2 • Normally Open (NO)

Diagram 3 • Other Accessories

NC2

COM2

NO2
NC1

COM1

NO1
BUT

GND

SEN

GND

+12V

DC12V

Electronic Door

Lock (Type NC)
Emergency

Break Glass

(Type NC)

Overwrite

Keyswithch

(Type NC)

Push Release

Button

DC12V 3A

Power Supply

+
_

2
3

A
C

NC2

COM2

NO2
NC1

COM1

NO1
BUT

GND

SEN

GND

+12V

DC12V

Electronic Door

Lock (Type NO)
Emergency

Break Glass

(Type NO)

Overwrite

Keyswithch

(Type NO)

Push Release

Button

DC12V 3A

Power Supply

+
_

1
3

B
D

*Door Sensor, Alarm, Doorbell.

NC2

COM2

NO2
NC1

COM1

NO1
BUT

GND

SEN

GND

+12V

Doorbell

Alarm Device

Type NC dry

contact

Alarm Device

Type NO dry

contact

Door Sensor

DC12V 3A

Power Supply

BEEL+

BEEL-

BEEP
GLED
RLED

INWD0
INWD1

Use either Type NO or Type NC alarm device.

Front View of i-Kiosk 100

Appendix II

Terminal Dimensions and Measurements

Appendix I

Power Supply & Door Lock System Wiring Diagrams

Door Lock Connectors

The terminal will trigger the alarm output (NO or NC)
for the following situations:
• Door forced open (A door sensor must first be in-

stalled)

• Door open time out (A door sensor must first be in-

stalled)

• Terminal has been illegally dismantled

Dry Contact

(Independent power supply for door lock)

• NO type door lock (NO1-COM)

• NC type door lock (NC1-COM)

Power Contact

(Using power from terminal to power on door lock)

• NO type door lock (NO-GND)

• NC type door lock (NC-GND)

Dry Contact

(Independent power supply for door lock)

• NO type door lock (NO1-COM)

• NC type door lock (NC1-COM)

Power Contact

(Using power from terminal to power on door lock)

• COM1 - +12V

Alarm System

NO Type – NO2 – COM2

NC Type – NC2- COM2

Door Sensor (SEN-GND)

Release Button(BUT-GND)

Door Bell

WIRING PORT USAGE

NO1
NC1

COM1

NO2

COM2

NC2

SEN

GND

BUT

Bell+

Bell-