Enable illegal dismantle alarm, Apply multi verification method, Enable fail verification alarm – FingerTec H3i Installation Guide User Manual

Page 2: Finalizing the installation, Appendix • terminal dimensions and measurements, Door lock accessories

Advertising
background image

Note: Press 1 to disable this feature if you do not want to link up H3i
with an alarm or siren system.

To turn off alarm output: Verify your Admin password > Press #

ENABLE ILLEGAL DISMANTLE ALARM

H3i will trigger the alarm or siren system immediately if
somebody tries to dismantle it.

Operation: Verify your Admin password > Green LED
blinks > Buzzer emits long beep > Press 7 > Green LED
blinks > Buzzer emits long beep > Press 0 > Green LED
blinks > Buzzer emits long beep > Changes done success-
fully

Note: Press 1 to disable this feature if you do not want to use it.

APPLY MULTI VERIFICATION METHOD

You can increase your access control’s security level by
applying multiple verification methods.

Operation: Verify your Admin password > Press 5 >
Green LED blinks > Buzzer emits long beep > Insert
number to represent the type of multi verification (as per
table shown) > Green LED blinks > Buzzer emits long
beep > Multi verification applied successfully

NUMBER MULTI

VERIFICATION

1

Password

only

2

Card

only

3

Fingerprint

only

4

Fingerprint/Card/Password

5

Card + Password

6

Fingerprint + Password

ENABLE FAIL VERIFICATION ALARM

Enable device to trigger alarm or siren system when a
user fails to verify more than 3 continuous times.

Operation: Verify your Admin password > Press 0 >
Green LED blinks > Buzzer emits long beep > Press 2 >
Green LED blinks > Buzzer emits long beep > Press 0 >
Green LED blinks > Buzzer emits long beep > Changes
done successfully

Note: Press 1 to disable this feature if you do not want to use it.

5

FINALIZING THE INSTALLATION

1. Check that all cable connections are done

correctly.

2. Attach the terminal to the corresponding back

plates and tighten the screws to secure the
terminal on the wall.

3. Switch on the power to the terminal.
4. Start using the terminal.

Diagram1 • Normally Close (NC)

Diagram 3 • Other Accessories

Door Lock Connectors

The terminal will trigger the alarm output (NO or NC)
for the following situations:
• Door forced open (a door sensor must first be

installed)

• Door open time out (a door sensor must first be

installed)

• Terminal has been illegally dismantled

APPENDIX • TERMINAL DIMENSIONS AND MEASUREMENTS

DC12V 3A

Power Supply

+12V

GND

BUT

GND

SEN
NO1

COM1

NC1

AL---
AL+

BELL---
BELL+

Door sensor

EM Lock (NC)

---
+

Emergency Break 2

Glass (Type NC)

3

Override Switch

A

(Type NC)

C

Release button

DOOR LOCK ACCESSORIES

FingerTec offers various door lock accessories to
complement FingerTec door access products. For
more info, go to http://accessory.fingertec.com.

APPENDIX • POWER SUPPLY & DOOR LOCK SYSTEM WIRING DIAGRAMS

Diagram 2 • Normally Open (NO)

DC12V 3A

Power Supply

+12V

GND

BUT

GND

SEN
NO1

COM1

NC1

AL---
AL+

BELL---
BELL+

Door sensor

EM Lock (NO)

---
+

Emergency Break 1

Glass (Type NO) 3

Override Switch

B

(Type NO)

D

Release button

DC12V 3A

Power Supply

Door Sensor

Alarm device Type NO

or NC Dry contact

+12V

GND

BUT

GND

SEN
NO1

COM1

NC1

AL---
AL+

BELL---
BELL+

WIRING PORT

NO

NC

COM

SEN

GND

BUT

AL+

AL-

USAGE

Dry Contact

(Independent power supply for door lock)

• NO type door lock (NO-COM)
• NC type door lock (NC-COM)
Power Contact

(Using power from terminal to power on door lock)

• NO type door lock (NO-GND)
• NC type door lock (NC-GND)

Dry Contact

(Independent power supply for door lock)

• NO type door lock (NO-COM)
• NC type door lock (NC-COM)
Power contact

(Using power from terminal to power on door lock)

• COM1 - +12V

Door Sensor (SEN-GND)
Release Button (BUT-GND)

Alarm System
NO or NC Type – Check in Advance Options

©

2013

FingerTec Worldwide Sdn. Bhd. All rights reserved • 062013

84 mm

84 mm

38 mm

38 mm

38 mm

38 mm

32 mm

10 mm

10mm

10mm

7mm

3mm

Front View of Terminal Back Plate

Advertising