Diagram1 • Normally Close (NC)

Diagram 2 • Normally Open (NO)

Diagram 3 • Other Accessories

NO2

COM2

NC2

SEN

GND

BUT

NO1

COM1

NC1

GND

+12V

Release Button

EM Lock

Emergency
Break Glass

Overwrite Key
Switch

+

_

1

3

B

D

DC12V

3A

_

+

NO2

COM2

NC2

SEN

GND

BUT

NO1

COM1

NC1

GND

+12V

Release Button

EM Lock

Emergency
Break Glass

Overwrite Key
Switch

+

_

2

3

A

C

DC12V

3A

_

+

Use either Type NO or Type NC alarm device.

NO2

COM2

NC2

SEN

GND

BUT

NO1

COM1

NC1

GND

+12V

_

+

Alarm Device

Type NC dry contact

Alarm Device

Type NO drycontact

Door Sensor

DC12V

3A

Door Lock Connectors

The terminal will trigger the alarm output
(NO or NC) for the following situations:

• Door forced open (A door sensor must

first be installed)

• Door open time out (A door sensor must

first be installed)

• Terminal has been illegally dismantled

Alarm System

NO Type – NO2 – COM2

NC Type – NC2- COM2

Door Sensor (SEN-GND)
Release Button (BUT-GND)

Dry Contact
(Independent power supply for door
lock)
• NO type door lock (NO1-COM)
• NC type door lock (NC1-COM)
Power Contact
(Using power from terminal to power
on door lock)
• NO type door lock (NO1-GND)
• NC type door lock (NC1-GND)

Dry Contact (independent power
supply for door lock)
• NO type door lock (NO1-COM)
• NC type door lock (NC1-COM)
Power Contact (using power from
terminal to power on door lock)
• COM1 - +12V

WIRING PORT USAGE

NO2

COM2

NC2

SEN

GND

BUT

NO1

NC1

COM1

Appendix II

Terminal Dimensions and Measurements

Appendix I

Power Supply & Door Lock System Wiring Diagrams

Front View of Back Plate

Advertising