FingerTec m-Kadex Installation Guide User Manual

Page 3

Advertising
background image

Diagram1 • Normally Close (NC)

Diagram 2 • Normally Open (NO)

Diagram 3 • Other Accessories

EM Lock (NO)

+

---

Emergency Break 1

Glass (Type NO) 3

Overwrite Switch B

(Type NO)

D

Release Button

DC12V 3A

Power Supply

ALM+

ALM-

NC

COM

NO

BUT

GND

SEN

BEL+

BEL-
GND

+12V

ALM+

ALM-

NC

COM

NO

BUT

GND

SEN

BEL+

BEL-
GND

+12V

Alarm device Type

NO or NC Dry contact

Door Sensor

Doorbell

DC12V 3A

Power Supply

EM Lock (NC)

+

---

Emergency Break 2

Glass (Type NC) 3

Overwrite Switch A

(Type NC)

C

Release Button

DC12V 3A

Power Supply

ALM+

ALM-

NC

COM

NO

BUT

GND

SEN

BEL+

BEL-
GND

+12V

Appendix II

Terminal Dimensions and Measurements

Appendix I

Power Supply & Door Lock System
Wiring Diagrams

Front View of m-Kadex

Door Lock Connectors

The terminal will trigger the alarm
output (NO or NC) for the follow-
ing situations:

• Door forced open (A door sen-

sor must first be installed)

• Door open time out (A door sen-

sor must first be installed)

• Terminal has been illegally dis-

mantled

Alarm System
(NO or NC Type – Check
in Advance Options)

Dry Contact (independ-
ent power supply for door
lock)
• NO type door lock (NO1-

COM)

• NC type door lock (NC1-

COM)

Power Contact (using
power from terminal to
power on door lock)
• NO type door lock (NO1-

GND)

• NC type door lock (NC1-

GND)

Dry Contact (independ-
ent power supply for door
lock)
• NO type door lock (NO1-

COM)

• NC type door lock (NC1-

COM)

Power Contact (using
power from terminal to
power on door lock)
• COM1 - +12V

Door Sensor
(SEN-GND)
Release button
(BUT-GND)

Door Bell

WIRING PORT USAGE

ALM+

ALM-

NC

NO

COM

BUT

GND

SEN

BEL-

BEL+

Advertising