Switch

1

2

3

4

5

6

Device ID

Status of DIP switch

58

*

ON

*

ON

ON

ON

59

ON

ON

*

ON

ON

ON

0

*

*

ON

ON

ON

ON

1

ON

*

ON

ON

ON

ON

2

*

ON

ON

ON

ON

ON

3

ON

ON

ON

ON

ON

ON

1. You can connect up to 3 units of Ingressus within the same network.

However 32 units of Ingressus is recommended for performance pur-

poses.

2. Switch 7 is the reset button of Ingressus. Turn ON and OFF 3 times within

10 sec to reset Ingressus back to factory default settings. The reset op-

eration erases all data and records stored in Ingressus.

3. Switch 8 is a resistor in between the RS485 + and RS485 – wires to main-

tain the strength of data signal. In case of installation with RS485 wires

longer than 300 meters, turn on switch 8 of the first and last Ingressus.

This action is to add a 123ohm resistor to the RS485 wires to maintain

the data signal strength.