FingerTec AC100 Series User Manual

Installation guide, Step 2 mounting of terminals, Ac100 series

Advertising
background image

TCP/IP PORT (LAN)

POWER ADAPTER
PORT

RS484 PORT

2. RS485 Network Connection

1. RS485 Single Connection

RX+

RX-

RS232/ RS485

Data Converter

RX+

RX-

RS232/ RS485

Data Converter

RS232 PORT

RS232/RS485 SERIAL
CABLE PORT

USB PORT

Wall

4 feet / 1.2 meter
(recommended)

Step 1

Determine the Location and Positioning

of the Installation

Avoid installing the terminals in locations that has contact with
a strong light source (e.g direct sunlight, spotlight, fluorescent
light, etc)

Avoid installing the terminals in locations with high moisture or

condensation levels in the air

The recommended installation height of the terminal from the
ground is 1.2 meters.

Step 2

Mounting of Terminals

A. MOUNT ON WALL

After determining the height of the terminal from the ground
level and having made the relevant marks on the wall, based on
the measurements in Appendix I, drill the screws into the wall to
hang the terminal.

Installation Guide

We Make Things Easy

w w w . f i n g e r t e c . c o m

AC100 Series

Fingerprint Time Attendance System

B. FLEXI- KIT

FingerTec offers flexi-kits for all its time attendance models. Attach
the terminal on the flexi-kit for convenience.

Step 3

Wiring for Power Supply

The power jack is positioned on top of the terminal, labeled
Power Adapter Port in the below diagram.

Please use the power adaptor provided in the package or alterna-
tively you can opt for a linear power supply with specifications of
5VDC 2A. Plug one point of the power adapter to the terminal and
the other end to the power outlet. Don’t exceed the recommended
voltage or current to avoid damaging the terminal.