Other features – FingerTec AdapTec-X User Manual

Page 6

Advertising
background image

6

1

2

3

4

OTHER FEATURES

You will find a buzzer, 3 LED indicators, and a door lock timer on the board. Check
and set each of them accordingly after powering up the system.

1

You will hear the buzzer beep to indicate

• Unlocked Door

Door is unlocked and access is granted (during verification or pressing push
release button).

• Over Voltage

(After startup)

Over voltage of power input (Stop the power supply to the system immedi-
ately and check the input voltage, consult

[email protected]

)

2

Adjust the door lock timer for a longer or shorter unlocking time period by turn-

ing the screw clockwise. Count the LED blinks after turning it. Each blink repre-
sents 1 second and the recommended time period is 5 seconds (5 blinks).

3

A switch to select the type of door lock to use, NO type or NC type.

4

The LED lights up to indicate the following:

•

EM lock LED -

The EM lock system is charged up and working properly.

• Status LED -

The overall system is working properly.

(

Note:

Contact

[email protected]

if either of the above LED lights are not lit up.)

•

Bat Low LED -

The battery is weak and needs to be charged or replaced.