Maximum Report Throughput

*Approximate rates. Throughput can vary with coordinate system and resolution setting.

Increment Mode

Command Sequence: <mode command><increment value>

Increment mode is an adjunct to Remote Request, Stream and Switch Stream modes. It is
useful for reducing redundant data output.

In Increment Mode, the tablet sends a report only when the stylus/cursor has traveled a
minimum distance in the X or Y direction. This minimum distance is the increment. It
applies to both axes and is measured in counts (of resolution). Its limits are 0 to 95 counts.

NOTE: When using Increment Mode, we recommend using a resolution setting of 50 lpi or
higher.

How Increment Mode Works

The last report issued becomes the center of an imaginary square. The square’s sides
measure twice the increment value. The stylus/cursor can move anywhere inside the
imaginary square without the tablet issuing a report. When the stylus/cursor touches the