GTCO MM II 1201 - Users Guide User Manual

Page 26

Advertising
background image

MM II 26


stylus/cursor button, the tablet reissues the last valid report twice, once the button
is pressed and again when it is released. (The difference between these reports is
the button flag. The flag is set when the button is pressed. It is zero when the
button is released.)

Switch Stream Mode and Axis Update Mode: If the update has not been met, the
tablet issues one report when a button is pressed. If the update has been met and
a button is pressed, the tablet can issue reports up to the established Report Rate.

Section B: Setting the Resolution

Resolution is the fineness of detail that the tablet can distinguish. Resolution is expressed
in lines per inch (lpi) or lines per millimeter (lpmm). (A detailed definition of resolution
appears in Chapter 1.) Two resolution functions are available, Predefined Resolution and
Definable Resolution.

Each time the tablet is turned on or issues the Reset command, the tablet defaults to a
resolution of 200 lpi.

Resolution, Predefined

ASCII command

Resolution setting of:
1 lpi
2 lpi
4 lpi
100 lpi
200 lpi
10 lpmm (254 lpi)
400 lpi
500 lpi
20 lpmm (508 lpi)
1000 lpi
40 lpmm (1016 lpi)


l (lowercase L)
n
p
d
e
f
g
h
i
j
q

Use these commands to set the tablet to one of the predefined resolutions listed above.

Advertising