Setup Mode 1 (stationary programming)

Setup Mode 1 is used to program the unit without the need to operate the vehicle.

Entering Setup 1

1. Press and hold Button 1 (left button) for TWO shift light blinks – MEDIUM press
2. The Dash will display SETUP 1?

3. Confirm by pressing Button 1 for ONE shift light blink – SHORT press

The following are in the order in which the individual programming features will appear.

Setting as
Displayed on

Dash

Program
Setting Description

Programming
Command

Accept and
Advance

Accept and
Exit


BACKLIGHT

0 = Off
9 = Max Brightness

Short Press
Button 2 to
increase value

Short Press
Button 1

Long Press
Button 1


TACH PULSES

Number of pulses ignition
fires per revolution
V8=4
4 Cyl=2
0=Min
20=Max

Short Press
Button 2 to
increase value

Short Press
Button 1

Long Press
Button 1


SHIFT STEP

Programs RPM between
each shift light. Example:
If shift point is 5000 rpm
with a 100 step, first shi ft
light illuminates at 4600
RPM. Multiply your Step
setting by 4 and subtract
from Shift Point to
determine start of shift
light

Short Press
Button 2
Advances by 10

Medium Press
Button 2
Decreases by 10

Long Press
Button 2
Quickly advances

Short Press
Button 1

Long Press
Button 1

SHIFT GEAR X
X=Gear number

Program shift point for
each gear.

Short Press
Button 2
Advances by 10

Medium Press
Button 2
Decreases by 50

Long Press
Button 2
Quickly advances

Short Press
Button 1

Long Press
Button 1