NX-4 Control


Page 20


AUXILIARY OUTPUT EVENT SELECTION

DATA


EVENT

DATA


EVENT

0

/


Burglary Alarm

26


Fire Trouble

1

/


Fire Alarm

27


Chime

2

/


24 Hour Alarm

28

/


Expander Trouble

3

/


Trouble Alarm

29


Dynamic Battery Test Time

4

/


Tamper Alarm

30


Open Period

5


Yelping Siren (Burglary)

31


Closed Period

6


Temporal Siren (Fire)

32


Listen-In

7


Any Siren

33


Line Seizure

8


Any Bypass

34


Ground Start

9


AC Fail

35


Fail To Communicate

10


Low Battery

36


Reserved

11

/


Duress

37


Program Mode

12

/


Aux 1 Keypad Zone

38


Download In Process

13

/


Aux 2 Keypad Zone

39


Reserved

14

/


Panic Keypad Zone

40


Short Circuit (Over-current)

15


Keypad Tamper

41


Box Tamper

16

/


Autotest

42


Siren Tamper

17


Alarm Memory

43


Any Open

18


Entry

44


Any Short

19


Exit

45


Any Fault (Open/ Short on Non-Fire Zone)

20


Entry or Exit

46

/


Any Alarm

21


Armed State

47


Beeping Keypad

22


Disarmed State

48

/


Code Entry (See note below)

23


Ready

49

˜ /


Key FOB Function 1

24


Not Ready

50

˜ /


Key FOB Function 2

25


Fire



Notes: When Event 48 is programmed, it is possible to program a user code's authorization to select which output(s)
a particular code will activate. When LED 8 is on for an authorization, then LEDs 1- 2 correspond to that code
activating outputs 1 & 2 respectively. (See programming the LED keypads on page 8.)

˜ Events 49 & 50 require NX-408E, NX-416E or NX-448E wireless receivers to operate.

/ If set to follow condition, these events will be 1 second.



LOCATION 51 - AUTOTEST CONTROL (4 segments, numerical data)

Segment 1:

Program a "1" if the interval is to be in hours; Program a "0" if in days. Add a

A2" to suppress the

daily test or a

A3" to suppress the hourly test if any report has been sent.


Segment 2:

Program the Autotest interval from 1-255 hours/days.


Segment 3:

Program the Autotest report hour in 24-hour format (if the interval is in hours, this segment is
ignored).


Segment 4:

Program the Autotest report time, number of minutes after the hour.