Interlogix NX-4 User Manual

Page 29

Advertising
background image

NX-4 Control


Page 27

LOC

PG

DESCRIPTION

DEFAULT

DATA

FORMAT OVERRIDE


Segment #1 (Circle Numbers To Program)


Segment #2 (Circle Numbers To Program)


18

16

1
2
3
4
5
6
7
8

On = 1800hz transmit; Off = 1900hz
On = 2300hz handshake; Off = 1400hz.
On = cksum parity; Off = double round parity
On = 2 digit event code; Off = 1 digit code
Reserved.
Reserved.
On = 20 p.p.s.; Off = 10 or 40 p.p.s.
On = 10 p.p.s.; Off = 20 or 40 p.p.s.

1
2
3
4
5
6
7
8

On = pager format (no handshake required)
On = 1400/2300 handshake
Reserved
Reserved
On = Contact ID
On = SIA
On = Contact ID or 4+3
On = DTMF




Segments #3 & #4 RESERVED


19

16


DOWNLOAD ACCESS CODE


8-4-8-0-0-0-0-0

_ _ _ _ _ _ _ _


20

16


RINGS TO ANSWER DOWNLOAD

8

_


DOWNLOAD CONTROL


Segment #1 (Circle Numbers To Program)


21

16

1
2
3
4
5
6
7
8

Enables two call answering machine defeat
Reserved
Requires callback before downloading
Shutdown control panel
Lock out local programming
Lock out communicator programming
Lock out download section
Enables callback at autotest interval

22

16


CALLBACK PHONE NUMBER

14-14-14-14-14-14-14-14-14-
14-14-14-14-14-14-14-14-14-

14-14

__ __ __ __ __ __ __ __ __

__ __ __ __ __ __ __ __ __

__ __


FEATURE SELECTION

23

16


Segment #1


Segment #2


Segment #3



1
2
3
4
5
6
7
8

Quick Arm
Re-Exit
Auto Bypass
Silent Panic
Audible Panic
Auxiliary 1
Auxiliary 2
Multi Keypress Tamper

1
2
3
4
5
6
7
8

LED extinguish enable
Require user code for bypassing zones
Bypass sounder alert
AC power/low battery sounder alert
Enables bypass toggle
Enables silent auto arm
Enables automatic instant
Reserved

1
2
3
4
5
6
7
8

Open/Close
Bypass
Restore
Trouble
Tamper
Cancel
Recent Closing
Exit Error


ENTRY/EXIT TIMERS

Segment #1 (Entry Time #1)

30

Segment #2 (Exit Time #1)

60

Segment #3 (Entry Time #2)

30

24

17

Segment #4 (Exit Time #2)

60

25

17


ZONES 1-8, ZONE TYPES (

Default Configuration)


3-5-6-6-6-6-6-6

_ _ _ _ _ _ _ _

Standard

(Default)

Zone

Types

Pg 25

1

2

3

4

5

6

7

8

9

10

DAY ZONE

24 HOUR AUDIBLE

ENTRY/EXIT DELAY 1

FOLLOWER W/ AUTO- BYPASS DISABLED

INTERIOR FOLLOWER W/ AUTO- BYPASS

INSTANT

24 HOUR SILENT

FIRE

ENTRY/EXIT DELAY 2

24 HOUR SILENT SUPERVISED

11

12

13

14

15

16

17

18

19

20

RESERVED

INTERIOR FOLLOWER W/CROSS ZONE

INSTANT ENTRY GUARD

ENTRY/EXIT DELAY 1 W/GROUP BYPASS

INTERIOR FOLLOWER W/GROUP BYPASS

INSTANT W/GROUP BYPASS

ENTRY/EXIT DELAY 1 W/TAMPER

INTERIOR FOLLOWER W/TAMPER & AUTO-BYPASS

INSTANT W/TAMPER

ENTRY/EXIT DELAY 2 W/TAMPER

Advertising