LOCAL TELEPHONE COMPANY INTERFACE INFORMATION


TELEPHONE CONNECTION REQUIREMENTS

Except for telephone company provided ringers, all connections to the telephone network shall be made
through standard plugs and standard telephone company provided jacks or equivalent in such a
manner as to allow for immediate disconnection of the terminal equipment. Standard jacks shall be so
arranged that if the plug connected thereto is withdrawn, no interference to the operation of the
equipment at the customers premises which remains connected to the telephone network, shall occur
by reason of such withdrawal.

INCIDENCE OF HARM

Should terminal equipment or protective circuitry cause harm to the telephone network, the telephone
company shall, where practical, notify the customer that temporary discontinuance of service may be
required. However, where prior notice is not practical, the telephone company may temporarily
discontinue service if such action is deemed reasonable in the circumstances. In the case of such
temporary discontinuance, the telephone company shall promptly notify the customer who will be given
the opportunity to correct the situation. The customer also has the right to bring a complaint to the FCC
if he feels the disconnection is not warranted.

CHANGES IN TELEPHONE COMPANY EQUIPMENT OR FACILITIES

The telephone company may make changes in its communications facilities, equipment, operations, or
procedures where such action is reasonably required and proper in its business. Should any such
change render the customers terminal equipment incompatible with the telephone company facilities,
the customer shall be given adequate notice to make modifications to maintain uninterrupted service.

GENERAL

The FCC prohibits customer provided terminal equipment be connected to party lines.

IMPORTANCE OF THE RINGER EQUIVALENCE NUMBER

The Ringer Equivalence Number (REN) of this device is 0.1B. This number is a representation of the
electrical load that it applies to your telephone line.

MALFUNCTION OF THE EQUIPMENT

In the event that the device should fail to operate properly, the customer shall disconnect the
equipment from the telephone line to determine if it is the customer’s equipment that is not functioning
properly. If the problem is with the device, the customer shall discontinue use until it is repaired.

EQUIPMENT INFORMATION

MANUFACTURER OF CONNECTING EQUIPMENT: CADDX CONTROLS, INC.
FCC REGISTRATION NUMBER: GCQUSA-33408-AL-E, RINGER EQUIVALENCE: 0.1 B

CALIFORNIA STATE FIRE MARSHAL LISTING


LISTING No: 7167-1249:105

CATEGORY:

Control Unit (Household)

DESIGN:

Model NX-4 combination household fire and burglary alarm control units.

RATING:

120 VAC primary, 16.5 VAC secondary; 12 VDC standby

INSTALLATION: In accordance with listee’s printed installation instructions, NFPA 72, applicable

codes & ordinances and in a manner acceptable to the authority having jurisdiction.
The system must have the secondary power supply capable of operating the system
for at least 24 hours (battery standby) in the normal condition and followed by not
less than 4 minutes of alarm as required by code.

APPROVAL:

Listed as household fire alarm control unit for use with separately listed compatible
initiating and indicating devices. The control unit can generate the three pulse
temporal code pattern fire alarm signal (for total evacuation) as required per NFPA
72, 1996 Edition.