Interlogix NX-4 User Manual

Page 37

Advertising
background image

NX-4 Control


Page 35

APPENDIX 3 EXPANDER NUMBERS FOR REPORTING EXPANDER TROUBLE


The tables below list the device numbers that will be reported for trouble conditions.

Device

Device # reported

NX-4 Control Panel

0

See pages 33 - 34 for possible report codes.

NX-534E Two Way Listen-In

64

NX-540E

AOperator@

40

NX-582E AES Interface

77

NX-591E Cellemetry Interface

76



KEYPADS

Keypad

1 2 3 4 5 6 7 8

Device #

192 200 208 216 224 232 240 248





REMOTE POWER SUPPLY (NX-320E)

OUTPUT

MODULE (NX-508E)

Address & Dip Switch Setting

Address & Dip Switch Setting

84 (All switches off) 88 (Switch 3 on)

24 (Switch 1 & 2 on)

28 (Switch 1,2,&3 on)

85 (Switch 1 on)

89 (Switch 1 & 3 on)

25 (Switch 3 on)

29 (All switches off)

86 (Switch 2 on)

90 (Switch 2 & 3 on)

26 (Switch 1 & 3 on)

30 (Switch 1 on)

87 (Switch 1 & 2 on)

91 (All switches on)

27 (Switch 2 & 3 on)

31 (Switch 2 on)




WIRELESS RECEIVER (NX-448E)

Switch Setting

Expander #

reported

All switches off

35

Switch 1 on

32

Switch 2 on

33

Switch 1 & 2 on

34


KEYPAD MAXIMUM WIRE RUN

(Note: These numbers are for one keypad at the end of the wire. When connecting more than one keypad to the end of
the wire, a higher gauge wire will be required.)

WHEN CONNECTED TO NX-4

WHEN CONNECTED TO NX-320E

Length in feet

Wire Gauge

Wire Gauge

250 24

22

500 20

18

1000 18

16

1500 16

14

2500 14

12