NX-4 Control


Page 29

LOC

PG

DESCRIPTION

DEFAULT

DATA

KEYPAD SOUNDER CONTROL
Segment #1 (Circle numbers to program)

39

18

1
2
3
4
5

6

7
8

Reserved.
Reserved.
Keypad sounds upon AC Power Failure.
Keypad sounds upon Low Battery Detection.
Keypad sounds during Cross Zone Trip Time.
Keypad sounds for Tamper Alarm.
Reserved.
Keypad sounds for expander trouble (required for UL).

SYSTEM TIMERS

Segment #1 Dynamic Battery Test duration (0-255 min.)

0

_

Segment #2 AC Failure report delay (0-255 minutes)

5

_

Segment #3 Power Up Delay (0-60 seconds)

60

_

Segment #4 Siren Time (1-255 minutes)

8

_

Segment #5 Reserved

0

_

Segment #6 Cross Zone Time (0-255 minutes)

5

_

Segment #7 Chime Time in 50 mS increments (0-255)

3

_

Segment #8 Dialer delay (15-255 seconds)

30

_

Segment #9 Fire Alarm Verification Time (120-255 sec.)

0

_

40

18

Segment #10 Listen-In Time (0-255 seconds)

0

_


USER CODE REQUIREMENTS


Segment #1 (Circle numbers to program)

41

19

1
2
3
4

5-8

Enables six-digit code option. All arm/disarm/Go To Program codes require six digits
Requires valid user code entry for [

r]-[9]-[8] and [r]-[9]-[9] functions to work.

Enables Auto Cancel/Abort.
Enables Walk Test mode.
Reserved.

42

19


GO TO PROGRAM CODE

9-7-1-3-0-0

_ _ _ _ _ _

GO TO PROGRAM CODE AND AUTHORIZATION
Segment #1 (Circle numbers to program)

43

19

1
2
3
4
5
6
7
8

Reserved.
Enables "Go To Program Code" as an arm only code.
Enables "Go To Program Code" as an arm only after closing.
Enables "Go To Program Code" as a master arm/disarm code (can change user codes)
Enables "Go To Program Code" as an arm/disarm code.
Enables "Go To Program Code" to bypass zones.
Enables "Go To Program Code" opening and closing reports.
Reserved.

44 19

DURESS

CODE

15-15-15-15-15-15

_ _ _ _ _ _

46

19 AUXILIARY OUTPUTS 1 & 2 SPECIAL TIMING

Segments

1

2



Auxiliary output timed in minutes.
Auxiliary output to latch.
Auxiliary output to stop timing upon user code entry.
Auxiliary output to activate only between closing and opening time.
Auxiliary output to activate only between opening and closing time.
Invert auxiliary output (0 volts going to 12 volts when activated).
Reserved
Reserved

1
2

3

4
5
6
7
8

1
2

3

4
5
6
7
8

Advertising