Chapter 2: Reporting codes

30

NX-8E Control Panel Installation Manual

Zone type

Description

6. Instant

Creates an instant alarm whenever it is tripped and the armed LED is
on.

7. 24-hour silent

Creates an instant silent alarm regardless of the armed state of the
control panel. It does not display on the keypad.

8. Fire

Illuminates the Fire LED and sounds the temporal siren each time the
zone is shorted. The Fire LED flashes rapidly indicating a problem if
the zone is open.

9. Entry/exit delay 2

A trip starts entry delay 2. The lack of a trip during exit delay enables
the automatic bypass or instant mode if programmed.

10. 24-hour silent
supervised

Creates an instant silent alarm regardless of the armed state of the
control panel. It displays on the keypad.

11. Keyswitch zone

Will arm and disarm the partitions of the control panel that it resides in
each time the zone is shorted. Keyswitch arming will report as user
number 99.

12. Interior follower with
cross zone

Instant when the system is armed and no entry or exit delay is being
timed. It is delayed during entry and exit delay times. If a cross zone is
not being timed, it starts a cross zone timer. If a cross zone is being
timed, it creates an instant alarm. It automatically bypasses when
enabled in Segment 1 of Location 23.

13. Instant entry guard

Creates an instant alarm whenever it is tripped and the Stay LED is
off. It starts an entry delay type 2 if it is tripped, the system is armed,
and the Stay LED is on.

14. Entry/exit delay 1
with group bypass

A trip starts entry delay 1. This zone bypasses when the group bypass
command is entered at the keypad. The lack of a trip during exit delay
enables the automatic bypass or instant mode if programmed.

15. Interior follower with
group bypass

Instant when the system is armed and no entry or exit delays are
being timed. It is delayed during entry/exit delay times. It bypasses
when the group bypass command is entered at the keypad. It
automatically bypasses if enabled in Segment 1 of Location 23.

16. Instant with group
bypass

Creates an instant alarm whenever it is tripped and the Armed LED is
on. Bypasses when the group bypass command is entered at the
keypad.

17. Entry/exit delay 1
with tamper

A trip starts entry delay 1. The lack of a trip during exit delay enables
the automatic bypass or instant mode if programmed. Is used to
enable the tamper on a wireless transmitter.

18. Interior follower with
tamper and autobypass

Instant when the system is armed and no entry or exit delay is being
timed. It is delay during entry and exit delay times. It automatically
bypasses if enabled in Segment 1 of Location 23. Is used to enable
the tamper on a wireless transmitter.

19. Instant with tamper

Creates an instant alarm whenever it is tripped and the Armed LED is
on. Is used to enable the tamper on a wireless transmitter.

20. Entry/exit delay 2
with tamper

A trip starts entry delay 2. The lack of a trip during exit delay enables
the automatic bypass or instant mode if programmed. Is used to
enable the tamper on a wireless transmitter.