Interlogix NX-8E Installation Manual User Manual

Page 52

Advertising
background image

Chapter 2: Reporting codes

48

NX-8E Control Panel Installation Manual

number. If the account code is six digits long, program
all six segments.

Location 108
Partition 8 feature and reporting
selection

Location 108 has five segments of feature selection
data. Use this location to enable certain features that
are accessed or visible to the user from the system
keypad. In addition, certain communicator reports are
enabled at this location. Each of these features can be
enabled by partition (Location 23).

Location 109
Partition 8 entry and exit times

Location 109 has six segments of numerical data. Use
this location to program the entry/exit times for partition
8. There are two separate entry/exit times (Location
24).

Locations 110 to 169 - Zone type characteristics

Locations 110 to 169 are considered advanced programming and you should
only change them with a thorough understanding of the operation of each bit.
Table 9 on page 49 lists the attributes for each location.

Caution:

We recommend the installer bench test any custom zone types to

ensure proper operation prior to making changes to a live system.

Even-numbered locations

Each even-numbered location has one segment of numerical data that programs
the alarm event code for Contact ID or SIA. If 4+2 format is used, the number
programmed in this location is sent as the upper hex digit. When using 4+2
formats, the digits are from 1 to 15. The zone ID or user ID is the lower hex digit
of the zone that is in alarm.

Odd-numbered locations

For odd-numbered locations, the defaults represent the five segments of each of
the locations separated by commas.

Segment 1

1. Fire. On if this is a fire zone.
2. 24-hour. On for nonfire 24-hour zones.
3. On for keyswitch zone (normally open).
4. Follower. On for burglary zones that are instant during nonentry times).
5. Delay 1 zone. One if zone follows timer 1 entry and exit times.
6. Delay 2 zone. On if zone follows timer 2 entry and exit times.
7. Interior. On if this zone automatically bypasses or bypasses for stay arming.
8. Local only. On if this zone is not to be reported..

Advertising