Appendix B: Reporting codes

NX-8E Control Panel Installation Manual

79

Loc. Description

Default

Setting

34

Zones 33 to 40 partitions

Segment 1 = 1 2 3 4 5 6 7 8

Segment 2 = 1 2 3 4 5 6 7 8

Segment 3 = 1 2 3 4 5 6 7 8

Segment 4 = 1 2 3 4 5 6 7 8

Segment 5 = 1 2 3 4 5 6 7 8

Segment 6 = 1 2 3 4 5 6 7 8

Segment 7 = 1 2 3 4 5 6 7 8

Segment 8 = 1 2 3 4 5 6 7 8

35

Zones 41 to 48 zone types

6, 6, 6, 6, 6, 6, 6, 6

36

Zones 41 to 48 partitions

Segment 1 = 1 2 3 4 5 6 7 8

Segment 2 = 1 2 3 4 5 6 7 8

Segment 3 = 1 2 3 4 5 6 7 8

Segment 4 = 1 2 3 4 5 6 7 8

Segment 5 = 1 2 3 4 5 6 7 8

Segment 6 = 1 2 3 4 5 6 7 8

Segment 7 = 1 2 3 4 5 6 7 8

Segment 8 = 1 2 3 4 5 6 7 8

37

Siren and system supervision

Segment 1

1 = Siren sounds for phone line cut while armed

2 = Siren sounds for phone line cut while

disarmed

3 = Siren blasts at arming

4 = Siren blasts at exit delay expiration

5 = Siren blasts at closing kissoff

6 = Siren sounds during a cross-zone verification time

7 = Siren sounds for a tam per

8 = Siren blasts one time for keysw itch, tw o times for

disarming

Segment 2

1 = Convert siren driver to voltage out

2 = Siren sounds for expander trouble

3 = Immediate restore by zone

4 = Dynamic battery test upon arming

5 = Battery missing test every 12 seconds

6 = Manual bell test during *, 4, 4 test function

7 = Manual communicator test during *, 4, 4 test

function

8 = Box tamper enabled

Segment 3

1 = Box tamper report enabled

2 = AC fail report enabled

3 = Low battery report enabled

4 = AUX pow er over current report enabled

5 = Siren supervision report enabled

6 = Telephone line cut report enabled

7 = Ground fault detection report enabled

8 = Expander trouble report enabled

Segment 4

1 = Failure to communicate report enabled

2 = Log full report enabled

3 = Autotest report enabled

4 = Start and end programming report enabled

5 = End dow nload report enabled

6 = Sensor low battery report enabled

7 = Sensor missing report enabled

8 = First to open/last to close enabled

Segment 5

1 = Lost clock service LED enabled

2 = Zone doubling enabled

3 = Disable on-board eight zones

4 = Enable tw o trips on the same cross-zone to

activate the alarm

5 = Disable bypass reports for force armed zones

6 = Reserved

7 = Clock uses internal crystal

8 = Disable temporal siren on fire

Segment 6

1 = Enable tw o-w ire smoke detector

2 = Reserved

3 = Enable zone activity in hours (not days)

4 = Enable Daylight Saving Time (DST)

5 = Reserved

6 = Disable Clean Me report

7 = Disable start/end test report

8 = Enable auto LED extinguish

Segment 7 = Reserved

38

Swinger shutdown count

1