Appendix A: Reporting codes

70

NX-8E Control Panel Installation Manual

Device numbers for reporting expander
troubles

The tables below list the device numbers that will be reported for trouble
conditions.

Table 16: Device numbers that report trouble conditions

Device

Name

Number

Control panel/modules

NX-8E control panel

Device address 0

NX-534E two-way listen in

Device address 64

NX-540E operator

Device address 40

NX-591E cell interface

Device address 76

NX-870E fire supervision

Device address 9

Hardware expander (NX-216E)

Zone 09 (all switches off)

Expander number reported 22

Zone 09 (switch 1 on)

Expander number reported 23

Zone 17 (switch 2 on)

Expander number reported 16

Zone 25 (switch 1 and 2 on)

Expander number reported 17

Zone 33 (switch 3 on)

Expander number reported 18

Zone 41 (switch 1 and 3 on)

Expander number reported 19

Zone 49 (switch 2 and 3 on)

Expander number reported 20

Zone 57 (switch 1, 2, 3 on)

Expander number reported 21

Zone 65 (switch 4 on)

Expander number reported 96

Zone 73 (switch 1 and 4 on)

Expander number reported 97

Zone 81 (switch 2 and 4 on)

Expander number reported 98

Zone 89 (switch 1, 2, 4 on)

Expander number reported 99

Zone 97 (switch 3 and 4 on)

Expander number reported 100

Zone 105 (switch 1, 3, 4 on)

Expander number reported 101

Zone 113 (switch 2, 3, 4 on)

Expander number reported 102

Zone 121 (switch 1, 2, 3, 4 on) Expander number reported 103

Zone 129 (switch 5 on)

Expander number reported 104

Zone 137 (switch 1 and 5 on)

Expander number reported 105

Zone 145 (switch 2 and 5 on)

Expander number reported 106

Zone 153 (switch 1, 2, 5 on)

Expander number reported 107

Zone 161 (switch 3 and 5 on)

Expander number reported 108

Zone 169 (switch 1, 3, 5 on)

Expander number reported 109