Keri Systems BioPointe Users Manual User Manual

Page 30

Advertising
background image

Administering the BioPointe

29

4.4.2 Enrolling a Next Master

When there are already one or more masters in the device, enrolling subsequent masters will first require a
master fingerprint verification. The following steps describe how to enroll subsequent masters.

Steps

LED and Buzzer Status


Press , , .

The LEDs will light up as shown in 1. The sensor
will also light up, waiting for a master fingerprint
to be placed and verified.



Place the master finger on the sensor to
verify.

a) If the finger is successfully verified as a
master, the 1

st

LED will blink green briefly as

shown in 2(a). Proceed to step 3.

b) If the finger is not successfully verified as a
master, the 1

st

LED will blink red briefly.

Operation will cease and return to normal mode.


When the 2

nd

LED starts to blink slowly

in red,
Enter a 4-digit ID.

a) If the 4-digit ID is accepted, the 2

nd

LED will

blink fast in red as shown in 3(a), and the sensor
will light up. Proceed to step 4.

b) If the ID is not accepted, the 1

st

LED will blink

red briefly as shown in 3(b). Operation will cease
and return to normal mode.




Place your finger on the sensor for the
enrollment when the sensor lights up.

Each successful enrollment requires 2 image
captures.

a) The sensor will go off after the first image has
been successfully captured, and a series of beep
sound will be heard. Proceed to step 5.

b) If the first capture is not successful, the 1

st

LED will blink red briefly as shown in 4.
Operation will cease and return to normal mode.





1

1

AMBER

RED

2

2a

GREEN
→AMBER

RED

AMBER

2b

RED
→AMBER




Master verification fails

3

3a

AMBER

RED

AMBER

3b

RED

→AMBER




ID not accepted

4

4

RED

→AMBER




1st capture not successful

1

Advertising