Cisco TelePresence System 3200

OL-14521-01

Chapter 9 Routing Power and Signal Cables

Power Requirements for the Cisco TelePresence 3200

Step 11

Connect the following cables to the auxiliary control unit:

•

Attach and route the power cables for the lighting assembly by connecting the lights to the auxiliary
control unit.

•

Connect the DSUB to 8-P MINI DIN cable between the projector and the auxiliary control unit.

•

Connect the Ethernet cables between the codec and the auxiliary control unit.

•

Connect the power cord for the auxiliary control unit to a wall outlet.

Figure 9-11

Cabling the Lighting Assembly Power Cables and Auxiliary Control Unit-to-Projector Serial Cable

Tip

Before plugging the Light fixture power cables into the unit, label each one. For example, 5’ Left light,
4’ Right light.