Specifications

Appendix O

YSI Incorporated

Environmental Monitoring Systems Operations Manual

O-11

pH
Sensor Type...........Glass combination electrode
Range.....................0 to 14 units
Accuracy................+/- 0.2 units
Resolution..............0.01 units
Temperature Range -5 to 50 C
Depth……………200 meters

ORP

Sensor type............ Platinum button

Range.....................-999 to +999 mV
Accuracy................+/-20 mV in redox standard solutions

Resolution...............0.1 mV
Temperature Range -5 to 60 C
Depth……………200 meters


Turbidity

Sensor type............ Optical, 90

scatter, with mechanical cleaning

Range..................... 0 to 1000 NTU
Accuracy................+/- 2% of the reading or 0.3 NTU (whichever is greater),

in YSI AMCO-AEPA standards

Resolution...............0.1 NTU
Temperature Range -5 to 50 C
Depth…………… 61 meters

Chlorophyll
Sensor type............ Optical, fluorescence, with mechanical cleaning

Range..................... Approximately 0 to 400 µg/L Chl; 0-100 Relative Fluorescence Units (RFU)
Accuracy................ No specification provided
Linearity................ R2 > 0.9999 for serial dilution of Rhodamine WT solution from 0 to 500 ug/L
Detection Limit…..Approximately 0.1 ug/L Chl (determined using cultures of Isochrysis sp. and chlorophyll a

concentration determined through extractions).

Resolution...............0.1 µg/L Chl; 0.1 RFU
Temperature Range -5 to 50 C
Depth…………… 61 meters

Phycocyanin-Blue-green Algae (BGA-PC)
Sensor type............ Optical, fluorescence, with mechanical cleaning

Range..................... Approximately 0 to 280,000 cells/mL of BGA (See Principles of Operation section for
explanation of estimate); 0-100 Relative Fluorescence Units (RFU)
Accuracy................ No specification provided.
Linearity................ R2 > 0.9999 for serial dilution of Rhodamine WT solution from 0 to 400 ug/L
Detection Limit...... Approximately 220 cells/mL. Estimated from cultures of Microcystis aeruginosa
Resolution...............1 cell/mL; 0.1 RFU
Temperature Range -5 to 50 C
Depth…………… 61 meters

Phycoerythrin-Blue-green Algae (BGA-PE)
Sensor type............ Optical, fluorescence, with mechanical cleaning

Range..................... Approximately 0 to 200,000 cells/mL of BGA (See Principles of Operation section for
explanation of estimate); 0-100 Relative Fluorescence Units (RFU)
Accuracy................ No specification provided.
Linearity................ R2 > 0.9999 for serial dilution of Rhodamine WT solution from 0 to 8 ug/L
Detection Limit...... Approximately 450 cells/mL. Estimated from cultures of a Synechococcus species.
Resolution...............1 cell/mL; 0.1 RFU
Temperature Range -5 to 50 C
Depth…………… 61 meters