Table 2 — physical data — unit 48sx – Carrier 48SX024-048 User Manual

Page 15

Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".

Advertising
background image

Table 2 — Physical Data — Unit 48SX

UNIT SIZE 48SX

024040

024060

030040

030060

030080

036060

036080

036100

036120

NOMINAL CAPACITY (ton)

2

2

2Уг

2Уг

2Уг

3

3

3

3

OPERATING WEIGHT (lb)

Without Base Rail

333

345

336

348

348

366

366

378

378

With Optional Base Rail

357

369

360

372

372

390

390

402

402

COMPRESSORS

Scroii

Quantity

REFRIGERANT (R-22)

Charge (lb)

39

39

4.5

45

45

54

5.4

54

5.4

REFRIGERANT METERING DEVICE

Acutrol'“ Device

Orifice ID (In.)

034

.034

.030

030

030

032

032

032

.032

CONDENSER COIL

Rows...Fins/in.

2.. 17

2.. 17

2.. 17

2.. 17

2.. 17

2.. 17

2.. 17

2.. 17

2.. 17

Face Area (sq ft)

7.0

70

70

70

70

70

70

7.0

70

CONDENSER FAN

Nominal Cfm

2200

2200

2200

2200

2200

2200

2200

2200

2200

Diameter (in.)

20

20

20

20

20

20

20

20

20

Motor Hp (Rpm)

У4 (1100)

'/4 (1100)

У4 (1100)

У4 (1100)

У4 (1100)

У4 (1100)

У4 (1100)

У4 (1100)

У4 (1100)

EVAPORATOR COIL

Rows Fins/in.

2. .15

2 15

3 15

3 15

3 15

4 15

4. 15

4 .15

4 15

Face Area (sq ft)

36

3.6

2 7

2.7

27

36

36

3.6

36

EVAPORATOR FAN

Direct Drive

Nominal Airflow (Cfm)

800

800

1000

1000

1000

1200

1200

1200

1200

Size (in.)

10

X

10

10

X

10

10

X

10

10

X

10

10

X

10

10

X

10

10

X

10

10

X

10

10

X

10

FURNACE SECTION*

Burner Orifice No. (Qty...drill size)

Natural Gas

1 32

2 38

1 32

2 38

2 32

2 38

2 32

3 36

3 32

Burner Orifice No. (Qty...drlll size)

Propane Gas

1 41

2 46

1 .41

2 .46

2.42

2. .46

2 42

3 ..44

3 42

RETURN-AIR FILTERS (in.)t

Disposable

24

X

24

24

X

24

24

X

24

24

X

24

24

X

24

24

X

24

24

X

24

24

X

24

24

X

24

UNIT SIZE 48SX

042060

042080

042100

042120

048080

048100

048120

048140

NOMINAL CAPACITY (ton)

ЗУг

ЗУ

2

ЗУ

2

ЗУ

2

4

4

4

4

OPERATING WEIGHT (lb)

Without Base Rail

391

391

403

403

422

434

434

434

With Optional Base Rail

415

415

427

427

446

458

458

458

COMPRESSORS

Scroll

Quantity

1

REFRIGERANT (R-22)

Charge (lb)

5.7

5 7

57

57

58

5 8

5.8

5.8

REFRIGERANT METERING

Acutrol" Device

DEVICE

Orifice ID (in.)

034

034

034

.034

.034

034

034

.034

CONDENSER COIL

Rows...Fins/in.

2.. 17

2.. 17

2.. 17

2.. 17

2.. 17

2.. 17

2.. 17

2.17

Face Area (sq ft)

87

8.7

87

8.7

8.7

8.7

87

8 7

CONDENSER FAN

Nominal Cfm

2400

2400

2400

2400

2400

2400

2400

2400

Diameter (in.)
Motor Hp (Rpm)

20

20

20

20

20

20

20

20

EVAPORATOR COIL

Rows Fins/in.

3...15

3 . 15

3.15

3 . 15

4.15

4.. 15

4.15

4 ..15

Face Area (sq ft)

4.4

44

44

44

44

4.4

4.4

44

EVAPORATOR FAN

Direct Drive

Nominal Airflow (Cfm)

1400

1400

1400

1400

1600

1600

1600

1600

Size (in.)

lOx 10

10

X

10

10

X

10

10

X

10

10

X

10

10

X

10

10

X

10

10

X

10

FURNACE SECTION*

Burner Orifice No.

(Qty...drill size)
Natural Gas

Burner Orifice No.

2. .38

2 32

3 36

3 .32

2 ..32

3 36

3 32

3.. 30

(Qty...drill size)
Propane Gas

2 46

2 42

3 44

3 42

2 .42

3 44

3 42

3.. 40

RETURN-AIR FILTERS (in.)t

Disposable

24

X

30

24 x30

24

X

30

24

X

30

24

X

30

24

X

30

24

X

30

816**

m

m

*Based on an altitude of 0-2000 feet
fRequired filter sizes shown are based on the ARI (Air Conditioning & Refrigeration Institute) rated heating airflow at

a velocity of 300 ff/min for disposable type or 450 ft/min for high-capacity type Air filter pressure drop must not
exceed 0.08 in. wg

**Sq inch Filter is mounted external to unit.

15

Advertising