Replacing the Slide Plate

You will not have any occasion to remove the slide plate.
However, if it should accidentally become disengaged from
the machine, it is easily replaced.

• Raise the presser foot and make sure needle is in its highest

position. Remove needle plate.

• Place slide plate in slide way with the front edge close to,

but not covering, the retaining spring (as shown).

• With a small screwdriver, lift each end of the spring into

each of the side grooves on the underside of the plate.

• Draw the plate gently toward you and fully engage the

spring.

• Replace needle plate and close slide plate.

Changing the Light Bulb

Caution; Before changing light bulb make sure you

have disconnected the power line plug from the socket
outlet

Caution: This machine is designed to use a 20 watt
maximum light bulb.

Removing Bulb.

With thumb of right hand, push in and

down on tab

A

of light lens and lower the light bracket.

Do

not attempt to unscrew the bulb. Press

it up into the

socket and at the same time turn bulb over in direction
shown to unlockthe bulb pin

B.

Replacing Bulb.

Press nevv bulb into socket, with bulb

pin

B

entering slot of socket, and turn it over in direction

shown to lock bulb in position. Push entire assembly
up until it snaps in position.