Introduction

• 5

General Purpose Timer/ Counter (GPTC)

Number of channel: 2 Up/Down Timer/Counters

Resolution: 16 bits

Compatibility: TTL/CMOS

Clock source: Internal or external

Max source frequency: 10MHz

Analog Trigger (A.Trig)

Source: external analog trigger (EXTATRIG)

Level:

±

10V external

Resolution: 8 bits

Slope: Positive or negative (software selectable)

Hysteresis: Programmable

Bandwidth: 400khz

External Analog Trigger Input (EXTATRIG)

Impedance: 40K

Coupling: DC

Protection: Continuous

±

35V maximum

System Synchronous Interface (SSI)

Trigger lines: 7

Calibration

Recommended warm-up time: 15 minutes

On-board reference: 5.0V

Temperature coefficient:

±

2ppm/

°

C

Long-term stability: 6ppm/1000Hr

Physical

Dimension: 175mm by 107mm

I/O connector: 68-pin female mini-SCSI type