4.1.3.1 Scan Timing and Procedure
There are 4 counters that need to be specified prior to programmable 
scans: 
Counter 
Name 
Width Description
Notes
SI_counter
24-bit
Scan Interval, which 
defines the interval 
between each scan. 
Scan Interval =
SI_counter / Time-
base* 
SI2_counter
24-bit
Sampling Interval, 
which defines the 
interval between 
each sampled 
channel. 
Sampling Interval =
 SI2_counter / 
Timebase* 
PSC_counter
24-bit
Post Scan Counts, 
which defines how 
many scans to be 
performed with re-
spect to each trig-
ger. 
Delay_counter 16-bit
Define the delay 
time for scan after 
trigger. 
Delay Time =
(Delay_counter / 
Timebase*), 
Timebase*=40M for DAQ/PXI-2500 Series
Table 4.1.4 Summary of Counters for Programmable Scan
The relationship between counters and acquisition timing is illustrated in 