Operation Theorem

• 21

Acquisition_in_progress

Scan_start

AD_conversion

Scan_in_progress

3 Scans, 4 Samples per scan

(PSC_Counter=3)

Sampling Interval t=
SI2_COUNTER/TimeBase

Scan Interval T=
SI_COUNTER/TimeBase

Ch0

Ch1

C h2

Ch3

Ch0

C h1

Ch2

Ch3

C h0

Ch1

C h2

C h3

(Scan acquisition is performed in ascending sequence for enabled channels)

Trigger

Figure 4.1.1 Timing for Scan

NOTE:
1. The maximum A/D sampling rate is 400KHz for DAQ/PXI-2500 series

therefore the minimum setting of SI2_counter is 100.

2. The Scan Interval can not be smaller than the interval of data Sampling

Interval multiple by the Number of channels per Scan, i.e.: SI_counter
>= SI2_counter * NumChan_Counter

4.1.3.2 Trigger Mode

Post-Trigger Acquisition

Use post-trigger acquisition when users want to perform scans right after a
trigger signal. The number of scans to be performed after the trigger signal
is specified by the PSC_counter, as illustrated in Figure 4.1.2. The total
acquired data length =

(number_of_channels_enabled_for

_scan_acquisition) * PSC_counter.

Delay Trigger Acquisition

Use delay trigger when users want to delay the scan after a trigger signal.
The delay time is determined by the Delay_counter, as shown in Figure
4.1.3.

The counter counts down on the rising edges of Delay_counter clock
source after the trigger signal. When the count reaches 0, DAQ/PXI-2500
SERIES starts to perform the scan. The acquired data length = (num-
ber_of_channels_enabled_for_scan_acquisition) * PSC_counter. The
Delay_counter clock source can be software selected from Internal 40MHz