Operation Theorem

• 19

4.1.2

Software Polling

This is the easiest way to acquire a single A/D data. The A/D converter
performs one conversion whenever the dedicated software command is
executed. The software would poll the conversion status and read the A/D
data back when it is available.

This method is suitable for applications that need to acquire A/D data in
real time. In this mode, the timing of the A/D conversion is fully controlled
by software. However, it would be difficult to maintain a fixed A/D sampling
rate.

4.1.3

Programmable Scan

This method is suitable for applications that need to acquire A/D data at a
precise and fixed rate. A scan is a group of multiple channel samples and
the scan interval is defined by the SI_counter. Likewise, the sample in-
terval of the multiple channels is defined by the SI2_counter. Please refer
to Table 4.1.4 for more information.

DAQ/PXI-2500 series can sample multiple channels in continu-
ous/discontinuous ascending sequence. For example, users may program
DAQ/PXI-2500 series to perform a scan in the channel sequence of
1-2-4-1-2-4…

There are 3 Trigger Modes available in Programmable Scan. They are
Post-Trigger, Delay-Trigger, Post/Delay-Trigger with Retrigger. Please
refer to Table 4.1.3 for a brief summary on Trigger Modes and their Trigger
Sources.

Trigger Mode

Description

Trigger Sources

Post-Trigger

Perform a scan right after the
trigger occurs.

Delay-Trigger

Scan delayed by the amount
of time programmed after the
trigger

Post/Delay-Trigger
with Retrigger

Perform repeated scan while
trigger occurs and it could be
under Post-Trigger or De-
lay-Trigger mode.

Software Trigger

Digital Trigger

Analog Trigger

SSI AD Trigger

Table 4.1.3 Trigger Modes and Corresponding Trigger Sources