ADLINK PXI-2502 User Manual

Page 48

Advertising
background image

40

• Operation Theoreym

4.4.2.5 Mode5: Single Triggered Pulse Generation

This function generates a single pulse with programmable delay and pro-
grammable pulse-width following an active GPTC_GATE edge. These
software programmable parameters can be specified in terms of periods of
the GPTC_CLK input. Once the first GPTC_GATE edge triggers the single
pulse, GPTC_GATE takes no effect until the software start is re-executed.
Figure 4.4.5 illustrates the generation of a single pulse with pulse delay of
two and pulse-width of four.

2

2

1

0

3

2

1

0

Gate

CLK

Count value

OUT

Software start

Figure 4.4.5 Mode 5 Operation

4.4.2.6 Mode6: Re-triggered Single Pulse Generation

This mode is similar to mode 5 except that the counter generates a pulse
following every active edge on GPTC_GATE. After the software start,
every active GPTC_GATE edge triggers a single pulse with programmable
delay and pulse-width. Any GPTC_GATE trigger that occurs during the
pulse generation would be ignored. Figure 4.4.6 illustrates the generation
of two pulses with pulse delay of two and pulse-width of four.

2

2

1

0

3

2

1

0

2

2

1

0

3

2

1

0

2

2

G a t e

C L K

C o u n t v a l u e

O U T

S o f t w a r e s t a r t

I g n o r e d

Figure 4.4.6 Mode 6 Operation

Advertising