ADLINK PXI-2502 User Manual

Page 38

Advertising
background image

30

• Operation Theoreym

NOTE: The maximum D/A update rate is 1MHz. Therefore the minimum
setting of UI_counter is 40.

(UC _Counter=4, IC_Counter=3)

4 update counts, 3 iterations

DAWR

WFG_in_progress

DA update_interval t=
UI_Counter/Timebase

Operation start

Trigger

Delay until
DLY1_Counter
reaches 0

Delay until
DLY2_Counter
reaches 0

Output Waveform

Delay until
DLY2_Counter
reaches 0

0

2

4

-4

A single waveform

UC_Counter=4

IC_Counter = 3

Figure 4.2.3 Typical D/A timing of waveform generation

(Assuming the data in the data buffer are 2V, 4V, -4V, 0V)

4.2.2.2 Trigger Modes

Post-Trigger Generation

Use post-trigger generation when users want to generate waveform right
after a trigger signal. The number of patterns to be updated after the
trigger signal is specified by UC_counter* IC_counter, as illustrated in
Figure 4.2.4.

Advertising
This manual is related to the following products: