ADLINK PXI-2502 User Manual

Page 30

Advertising
background image

22

• Operation Theoreym

Timebase, external input (AFI-1), or General Purpose Timer/Counter
Output 0/1.

Post-Trigger or Delay-trigger Acquisition with retrigger

Use post-trigger or delay-trigger acquisition with retrigger when users want
to perform repeated scans with respect to the repeated triggers. Figure
4.1.4 illustrates an example. Two scans are performed after the first trigger
signal, and then wait for the next trigger signal. When the trigger signal
occurs, it performs 2 more scans.

When re-trigger function is disabled, only one trigger signal would be ac-
cepted after retrigger

NOTE: Retrigger signals asserted during scan process will be ignored.

(NumChan_Counter=4, PSC_Counter=3)

Acquisition_in_progress

Scan_start

AD_conversion

Scan_in_progress

Acquired & stored data
(3 scans)

Operation start

Trigger

Figure 4.1.2 Post trigger

Advertising